14
|
Regency Horizon HZ30E-10 Gas Fireplace
|
14
installation
FRAMING DIMENSIONS
A
B
C
D
G
H
Non-Combustible
Facing
Metal Stud (Header)
F
E
I
J
K
L
Flex or Rigid Pipe
Finished Floor
Drywall or
other facing
C2
C1
Note: All other framing may
be of wood construction.
Note: T
horizontal
wo
steel studs must be
installed after the unit is in
position and the venting,
gas and electrical is
,
installed. The horizontal
studs allow the non-
combustible wall board to
be attached and
supported.
Metal Stud
on edge
Framing
Dimensions
Description
HZ30E
A
Framing Height
33-5/16” (946mm)
B
Framing Width
31 - 3/16" (792mm)
C
*
Framing Depth
*
C1
Horizontal Vent 15" (381mm)
C2
Vertical Vent, vertical rise - terminating horizonally - 21-1/4" (540mm)
D
Minimum Height to Combustibles
Rigid 35-1/2" (902mm) | Flex 32-7/8" (835mm)
E
Corner Wall Depth
43-5/16" ( 1100mm)
F
Corner Facing Wall Width
61-1/4" (1556mm)
G
Vent Centerline Height
Rigid 29-1/4" (743mm)
Flex 26-5/8" (676mm)
H
Non-combustible facing height
13-1/4” (367mm)
I
Gas Connection Opening Height
2" (51mm)
J
Gas Connection Height
3-1/4" (83mm)
K
Gas Connection Inset
4-1/8" (105mm)
L
Gas Connection Opening Width
3-1/2" (89mm)
*
Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.
The nailing strips can be adjusted back up to 3-1/8” to allow for varying thicknesses in non-combustible
material & wall finishes.
NOTE: If not purchasing the optional steel stud kit - adhere to the same framing if purchasing steel studs elsewhere. The use of the optional kit is highly
recommended as it was designed specifically for the product to facilitate ease of installation.