8 |
Greenfire® GF1500L-2 Gas Fireplace
installer's information
This includes:
1. Clocking the appliance to ensure the correct
firing rate (noted on label) after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
Locating Your Gas Fireplace
1. When selecting a location for your fireplace,
ensure that the clearances are met.
Diagram 1
2. The appliance must be installed on a flat, solid,
continuous surface. For example, a wood, metal,
or concrete floor or in a raised (on the wall)
application. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The GF1500L Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C and D. See diagram
1.
8. Test Gas Pressure (Refer to "Gas Pipe Pressure
Testing" section).
9. Install standard and optional features. Refer to
the following sections:
a) Log Install
b) Faceplate / Door Frame Overlay
c) Remote Control
10. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and its
operation fully explained to
customer.
Installation Checklist
1. Locate the appliance:
a) Room location (Refer to "Locating Your Gas
fireplace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Flueing Requirements (Refer to "Flue"
section)
2. Assemble the standoffs and nailing strips (refer
to "Unit Assembly Prior to Installation").
3. Slide unit into place.
4. Install flue (Refer to "Flue Arrangement"
sections).
5. Make gas connections (Refer to "Gas Line
Installation section).
6. Pair up Remote Control (Refer to "Pairing up
Remote Handset" section)
7. Test the pilot (Refer to "Pilot Adjustment"
section).
4. The GF1500L Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
5. We recommend that you plan your installation on
paper, using exact measurements for clearances
and floor protection, before actually installing
this appliance. Have an authorized inspector,
dealer, or installer review your plans before
installation.
PACKAGING:
The unit and its contents are packaged to
prevent damage during transport.
After unboxing, remove the plastic wrap then
the screws that secure the unit to the pallet.
Before commissioning of the unit, unwrap
each log and set aside. Before installation
of the logs, removal of the sheet metal cover
that protects the burner is required.
Refer to subsequent instructions on proper
set up and safety check before placing unit
into commission.
NO
TE
• Not intended for use as a fireplace insert.
Do not install in a fireplace.
NO
TE
• For flue terminations refer to "Exterior Flue
Termination Locations" section.
A)
Flat on wall
B)
Flat on wall corner
C)
Recessed into wall/alcove
D)
Corner
CA
UTION
• Any alteration to the product that causes
sooting or carboning that results in damage
is not the responsibility of the manufacturer.