10
E33 FPI Direct Vent Gas Insert
INSTALLATION
MINIMUM CLEARANCES TO COMBUSTIBLES
From Unit
Side Walls
*
A
8" (203 mm)
Ceiling
B
47" (1194 mm)
Min. Mantel Height C
15" (381 mm)
Max. Mantel Depth D
12" (305 mm)
Alcove Width
E
76" (1930 mm)
Alcove Depth
F
36" (914 mm)
Hearth Height
G
1-1/4" (32 mm)
Hearth Width
H
45-1/2" (1156 mm)
Hearth Depth
I
13" (330 mm)
* Alcove side wall must have a min. of 8"
clearance on one side.
COMBUSTIBLE MANTEL CLEARANCES
Because of the extreme heat this fi replace emits, the mantel clear-
ances are critical.
Note: A non-combustible mantel may be installed at a lower height
if the framing is made of metal studs covered with a non-
combustible board.
Mantel can be installed anywhere in shaded area or higher using the
above scale.
Note: Ensure the paint that is used on the mantel and the facing
is "heat resistant" or the paint may discolour.