background image

4

 | 

Regency I2400M

 | 

4

safety decal

This is a copy of the label that accompanies 

your 

Regency Insert

. We have printed a copy 

of the contents here for your review.

NOTE: 

 Regency units are constantly being 

improved.  Check the label on the unit and if 

there is a difference, the label on the unit is the 

correct one.

Part #:  

 

918-176f

Size: 

 

3"

 H

 x

 20-1/2"

 W

 (file

 at

 100%)

Colour: 

Black

 on

 grey

, except

 for

 what

 is

 indicated

 as

 being

 printed

 red

 on

 grey

.

June

 20/07:

 updated

 logo

 as

 per

 SCC

 requirements.

Mar

. 1/10:

 Updated

 Logo

Apr

. 7/1

1:

 Updated

 date

 of

 manufacture

 /  

added

 5.5"

 liner

Oct.

 3/13

 Rev

 D

 - 

updated

 yr

 of

 manufacture

May

 5/15:

 Rev

. E

 - 

added

 French

May

 2/16:

 Rev

. F

 - 

updated

 yr

 of

 manufacture

 2017-2021

SIGNATURE

Jan

    

Feb

   

Mar

    

Apr

   

May

    

June

July

   Aug

   

Sept

   

Oct

    

Nov

    

Dec

DATE

 OF

 

MANUFACTURE

INS

TAL

L AND 

US

E O

NL

Y I

N ACCO

RDANCE

 W

IT

THE

 M

ANUF

ACT

URE

R'

S I

NS

TAL

LA

TI

ON 

AND 

OP

ERA

TI

NG

 INS

TRUCT

IO

NS

.  INS

TAL

L AND 

US

E O

NL

Y I

MAS

ONR

FIREPLACE OR F

ACT

OR

Y BUIL

T FIREPLACE.  CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS 

AND INST

ALLA

TION INSPECTION IN 

YOUR AREA. INST

ALLER ET UTILISER SELONS LES INSTRUCTIONS DU F

ABRICANT

. INST

ALLER ET UTILISER DANS UN FOYER DE MACONNERIE OU PRÉF

ABRIQUÉ.

APPELER VOTRE INSPECTEUR DE BÂTIMENT OU LE DÉP

ARTMENT D’INCENDIE LOCAL

 POUR LES CODES LOCAUX ET POUR INSPECTÉE

VOTRE INST

ALLA

TION ET FOYER.

LISTED F

ACT

OR

Y BUIL

T FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA

 AND U.S.A.

MODEL: 

I2400M

TESTED T

O: ULC-S628-93 / UL-1482 / UL-737

REPORT NO.: 219-S-03-2

THE I2400M MEETS UL-737 ST

ANDARD FOR FIREPLACE ST

OVES WHEN 

A FIRESCREEN IS PROVIDED.

DO NOT REMOVE THIS LABEL

246

MINIMUM CLEARANCES T

 

COMBUSTIBLE MA

TERIALS  (MEASURED 

FROM INSERT BODY)

ADJACENT 

 

SIDEW

ALL

 

A)

 1

1 in / 280 mm

MANTLE

 

B)

 20 in / 508 mm

TOP

 FACING

 

C)

 12 in / 305 mm

SIDE F

ACING

 

D)

 8 in /  200 mm

COMPONENTS REQUIRED FOR INST

ALLA

TION:   5.5" (140mm) or 6" (152mm) ST

AINLESS STEEL

 LINER.

OPTIONAL

 COMPONENT

: F

AN (142-917), ELECTRICAL

 RA

TING: VOL

TS 1

15, 60 HZ, 0.6 

AMPS, SCREEN DOOR (846-102)

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SER

VICING UNIT

. DO NOT ROUTE POWER CORD UNDER OR IN 

FRONT OF 

APPLIANCE. DO NOT CONNECT THIS UNIT T

A CHIMNEY

 FLUE SER

VICING 

ANOTHER 

APPLIANCE. DO NOT REMOVE BRICKS 

OR MORT

AR IN MASONR

Y FIREPLACE.  FOR USE WITH SOLID WOOD FUEL

 ONL

Y.  DO NOT USE GRA

TE OR ELEV

ATE FIRE.  BUILD WOOD 

FIRE DIRECTL

Y ON HEARTH.  RISK OF SMOKE 

AND FLAME SPILLAGE, OPERA

TE ONL

Y WITH DOORS FULL

Y OPEN OR FULL

Y CLOSED. IF 

INST

ALLED IN 

A MOBILE HOME OPERA

TE ONL

Y WITH DOORS FULL

Y CLOSED - OPEN FEED DOOR T

O FEED FIRE ONL

Y. WHEN OPER

-

ATED WITH DOORS OPEN THE MANUF

ACTURER SUPPLIED SCREEN MUST BE USED.  REPLACE GLASS ONL

Y WITH CERAMIC GLASS 

(5MM).  INSPECT 

AND CLEAN CHIMNEY

 FREQUENTL

Y.   UNDER CERT

AIN CONDITIONS OF USE CREOSOTE BUILDUP

 MA

Y OCCUR RAP

-

IDL

Y.  DO NOT OVERFIRE, IF INSERT GLOWS 

YOU 

ARE OVER-FIRING.

PIÈCES NÉCESSAIRES POUR INST

ALLA

TION :5.5" (140MM) OR 6" (152MM) CONDUITS EN 

ACIER INOXYDABLE.

COMPOSANT F

ACUL

TA

TIF : VENTILA

TEUR (142-917); CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES : 1

15 VOL

TS, 60 HZ, 0,6 

A, P

ARE-

ÉTINCELLES (846-102) DANGER : RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHER L

’APP

AREIL

 A

VANT T

OUTE RÉP

ARA

TION. NE P

AS F

AIRE P

ASSER LE FIL

 

ÉLECTRIQUE DEV

ANT L

’APP

AREIL

 NI EN DESSOUS. NE P

AS RELIER CET 

APP

AREIL

 À UNE CHEMINÉE DESTINÉE À L

’ÉV

ACUA

TION D’UN 

AUTRE 

APP

AREIL. NE P

AS ENLEVER DE BRIQUES NI DE MORTIER D’UNE CHEMINÉE DE MAÇONNERIE. N’UTILISER QUE DU COMBUS

-

TIBLE DE BOIS SOLIDE. NE P

AS SURÉLEVER LES BÛCHES NI LES PLACER SUR DES GRILLES, MAIS LES DÉPOSER DIRECTEMENT 

SUR L

’ÂTRE. RISQUE DE DÉGAGEMENT DE FUMÉE OU DE FLAMMES : T

OUJOURS GARDER LES PORTES COMPLÈTEMENT OUVERTES 

OU FERMÉES LORSQUE L

’APP

AREIL

 FONCTIONNE. DANS UNE MAISON MOBILE, T

OUJOURS GARDER LES PORTES BIEN FERMÉES 

LORSQUE L

’APP

AREIL

 FONCTIONNE. OUVRIR LA

 PORTE UNIQUEMENT POUR 

ALIMENTER LE FEU. SI LES PORTES DU POÊLE RESTENT 

OUVERTES, T

OUJOURS UTILISER LE P

ARE-ÉTINCELLES FOURNI P

AR LE F

ABRICANT

. REMPLACER LA

 VITRE UNIQUEMENT P

AR UNE 

VITRE EN VITROCÉRAMIQUE (5 MM). INSPECTER ET NETT

OYER FRÉQUEMMENT LA

 CHEMINÉE. SELON LE TYPE D’USAGE, LE CRÉO

-

SOTE PEUT S’ACCUMULER RAPIDEMENT

. NE P

AS SURCHAUFFER; SI L

’ENCASTRABLE SE MET À ROUGIR, IL

 SURCHAUFFE.

CAUTION

 / A

TTENTION

HOT WHILE IN OPERA

TION  DO NOT T

OUCH.  KEEP

 CHILDREN,

 

CLOTHING 

AND 

FURNITURE 

AW

AY

.  

CONT

ACT 

MA

CAUSE 

SKIN BURNS.   READ 

ABOVE INSTRUCTIONS.

CHAUD LORS DE FONCTIONNEMENT

.

NE P

AS T

OUCHER. GARDEZ LES ENF

ANTS, VÊTEMENTS ET

  

MEUBL

ES

 AU L

OI

N.

 UN CO

NT

ACT

 A

VE

C L

E PE

AU P

EUT

  

OCCASIONER DES BRULURES.BRÛLURES CUT

ANÉES. LIRE

 

CETTE ÉTIQUETTE.

INST

ALL

 ONL

ON 

NON-COMBUSTIBLE 

HEARTH RAISED (F) 

0.5IN / 

13MM 

ABOVE 

AN 

ADJACENT COMBUSTIBLE 

FLOOR. 

 COMBUSTIBLE 

FLOOR 

MUST 

BE PROTECTED 

BY

 NON-COMBUSTIBLE 

MA

TERIAL

 EXTENDING (E) 18 IN / 457 MM T

O  FRONT 

AND (G) 8 IN / 205 MM T

O SIDES FROM FUEL

 DOOR. 0.5" FLOOR 

PROTECTION 

NEEDS 

TO BE WITH k=0.84.

INST

ALLER SUR UN ÂTRE DE MA

TÉRIAU NOM COMBUSTIBLE SURÉLEVÉ (F) 0,5 POUCES / 13MM-DESSUS DU PLANCHER COMBUSTIBLE 

ADJACENT

.

LE PLANCHER COMBUSTIBLE DOIT 

ÊTRE PROTÉGÉ 

PAR LE MA

TÉRIAU NOM COMBUSTIBLE QUI ÉTENDRE (E) 18 IN / 457MM À L

’A

VANT ET (G) 8 PO / 205 MM DE 

CHAQUE CÔTÉ DE LA

 PORTE. LE REVÊTEMENT DE PLANCHER DOIT 

AVOIR UNE ÉP

AISSEUR DE 0,5 PO ET UN COEFFICIENT K DE 0,84.

MADE IN

 CANADA

918-176e

(Duplicate Serial

 #)

  

246

Manufactured By

FIREPLACE PRODUCTS INTERNATIONAL

 LTD.

6988 VENTURE ST.,  DEL

TA,  BC    V4G 1H4

2017

2018

2019

2020

2021

 

918-176f

SAFETY LABEL FOR I2400M

Summary of Contents for classic i2400m

Page 1: ... I2400M Wood Fireplace Insert 12 15 16 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com French Manual http ow ly Zvzjy Manuel en Français http ow ly Zvzjy ...

Page 2: ...ority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY OTHER MATERI...

Page 3: ...Fireplace 9 Stainless steel smoke deflector Installation 10 Step by step Installation 11 Of The Faceplate And Trim 11 Step by step Installation Of The Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door Handle 13 Screen Door 13 Seasoned wood 14 First Fire 15 Some Safety Guidelines 15 Wood Storage 16 Ash Disposal 16 Fan Operat...

Page 4: ...RER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING PIÈCES NÉCESSAIRES POUR INSTALLATION 5 5 140MM OR 6 152MM CONDUITS EN ACIER INOXYDABLE COMPOSANT FACULTATIF VENTILATEUR 142 917 CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES 1...

Page 5: ...Regency I2400M 5 5 dimensions 5 5 9 ...

Page 6: ... manual before you installanduseyournewwoodinsert Failure to follow instructions may result in property damage bodily injury or even death Install anduseonlyinaccordancewithmanufactur er s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may overr...

Page 7: ...move it into position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The convection grills are installed before the unit is positioned inside the fireplace Positionthegrillontheinsidebodyfacesideand fastenusingth...

Page 8: ...EARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The specified floor protector should be 3 8 18mm thick material with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with ...

Page 9: ...mneydependsonthelengthofthe chimney local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the appliance and may cause damage An uncontrollable burn or excessivetemperatureindicatesexcessivedraft Inadequatedraftmaycausebackpuffingintothe room and plugging of the chimney Inadequate draft will cause the appliance to leak smoke into the room through a...

Page 10: ...oth bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door op...

Page 11: ...red width 4 The unit may now be slid into final position and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed with insulation stripbehind byaligningitsbracketswiththe top flange on the side shields and the angle iron bar on the insert top The faceplate trim m...

Page 12: ...mperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset ...

Page 13: ...the air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side Use a pair of vise grips or pliers and tap it into place with a hammer A tighter fit will FLUE BAFFLE SECONDARY AIR TUBE INSTALLATION The flue baffle sys...

Page 14: ...ds like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possib...

Page 15: ...urn dry standard fire wood only The use of mill ends is discour aged as this fuel can easily overheat your insert Evidence of excessive overheating will void your warranty As well a large por tion of sawmill waste is chemically treated lumber whichisillegaltoburninmanyareas Chemically treated fire logs also must not be burned in your insert WARNING Fireplace Stoves equipped with doors shouldbeoper...

Page 16: ...fluelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fan is not to be oper ated when the draft control rod is in the closed position pushed in The fully closed position is the low burn setting The fan unit must not be turned on until a fire has been burn...

Page 17: ...triking or slamming shut GLASS REMOVAL Allowthestovetocoolbeforeremovingorreplacing glass Remove the door from the insert and remove the glass retainer Use caution when removing broken glass to prevent injury When placing the replacement glass in the door makesurethattheglassgasketingwillproperlyseal yourunit Replacetheretainerandtightensecurely but do not wrench down on the glass as this may caus...

Page 18: ...10 24 Zinc Coated 44 Washer 10 Flat 45 Bolt 10 24 x 3 4 Blk Carriage 47 846 102 Screen Door 948 223 Regency Logo Nickel 48 820 482 Smoke Deflector 919 543 Manual Not available as a replacement part Part Description 1 850 151 Door Assy Large Black 850 153 Door Assy Large Nickel Accent 2 846 304 Glass Replacement 4 936 243 7 8 Adhesive Tape Gasket 5 846 920 Glass Retainer Clips Screws 8 set 6 Screw ...

Page 19: ...gular 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Page 20: ...cy I2400M 20 parts list BRICK PANELS I2400M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Page 21: ...Regency I2400M 21 21 notes ...

Page 22: ...Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective ...

Page 23: ... type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados ea...

Page 24: ...ial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your ad...

Page 25: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANA...

Page 26: ......

Page 27: ......

Page 28: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _______________________________________...