Regency I2400M
|
9
9
|
installation
1)
Positive Flue
Connection
with Cleanout
FLUE CONNECTOR
BRACKET
Package contains: 3 brackets and 6 screws.
These brackets are to be used to hold the flue
liner (not supplied) to the Insert and keep the
connection. The brackets are screwed into the
top of the Insert in the pre-punched holes and
then screwed into the flue liner.
INSTALLATION INTO A
MASONRY FIREPLACE
The insert must be installed as per the require-
ments of your local inspection authority. Three
methods of flue connection are acceptable in
most areas in the US, however
a full flue liner
is required in Canada.
1)
Positive flue connection, where a large
blocking plate and a short connector pipe
is used.
2)
Direct flue connection, where a smaller
blocking plate and a connector pipe to the
first flue liner tile is used.
3)
Full flue liner, where a stainless steel rigid
or flexible liner pipe is routed from the insert
outlet collar to the top of the chimney.
Regency highly recommends the use of a full
liner as the safest installation and provides the
most optimum performance. Your retailer should
be able to help you decide which system would
be the best for your application.
Note: A clean-out door is sometimes
required, by your inspector, to be
installed when either the Positive flue
connection or Direct flue connection
method is used.
Flush Inserts
2)
Direct Flue
Connection
with Cleanout
3a)
Full Flue Liner
(No Cleanout Required)
The use of one of the connection methods listed
on this page not only increases the safety of your
insert by directing the hot gases up the flue, but
will also help increase the unit's efficiency and
decrease creosote deposits in the chimney.
When a connected flue or liner is in use, the
insert is able to “breathe” better by allowing a
greater draft to be created. The greater draft can
decrease problems such as, difficult start-ups,
smoking out the door, and dirty glass.
Draft is the force which moves air from the ap-
pliance up through the chimney. The amount of
draft in your chimney depends on the length of the
chimney, local geography, nearby obstructions
and other factors. Too much draft may cause
excessive temperatures in the appliance and
may cause damage. An uncontrollable burn or
excessive temperature indicates excessive draft.
Inadequate draft may cause back puffing into the
room and plugging of the chimney. Inadequate
draft will cause the appliance to leak smoke
into the room through appliance and chimney
connector joints. Ensure the heater is installed
in areas that are not too close to neighbors or
in valleys that would cause unhealthy air quality
or nuisance conditions.
STEP-BY-STEP
INSTALLATION INTO A
FACTORY BUILT
FIREPLACE
1)
When installed in a factory built fireplace, a
full stainless steel rigid or flexible flue liner
is mandatory, for both safety and perform-
ance purposes. When a flue or liner is in
use, the insert is able to breathe better by
allowing a greater draft to be created. The
greater draft can decrease problems such
as, difficult start-ups, smoking out the door,
and dirty glass.
2)
In order to position the flue liner, the exist
-
ing rain cap must be removed from your
chimney system. In most cases the flue
damper should also be removed to allow
passage of the liner.
3)
In most cases opening the existing spark
screens fully should give enough room for
the insert installation. If it does not, remove
and store.
4)
If the floor of your fireplace is below the
level of the fireplace opening, adjust the
insert's levelling bolts to accommodate the
difference. When additional shimming is
required, use non-combustible masonry or
steel shims.
5)
Measure approximately the alignment of
the flue liner with the position of the smoke
outlet hole on the insert to check for pos-
sible offset. If an offset is required, use a
proper stainless steel unit available with the
chimney liner.
6)
Once the above items have been checked,
slide your insert into position after first po
-
sitioning the flue liner and offset if required.
(Re-install raincap at completion of installa-
tion).
NOTE: Refer to "Requirements for Installing
Solid-fuel Inserts in Factory-built Fire
-
places" section for the requirements
for installing solid fuel inserts in factory
built fireplaces.
Summary of Contents for classic i2400m
Page 5: ...Regency I2400M 5 5 dimensions 5 5 9 ...
Page 21: ...Regency I2400M 21 21 notes ...
Page 26: ......
Page 27: ......