requirements
installer's information
Locating Your Gas Fireplace
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CV72E Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C, and D.
See Diagram 1.
A) Flat on Wall-CV72E
Diagram 1
B) Flat on Wall Corner-CV72E
C) Recessed into Wall/Alcove-CV72E
D) Corner-CV72E
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CV72E Direct Vent Gas Fireplace is ap-
proved for alcove installations, see "Clearances"
section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior Vent
Termination Locations" section.