U900E-11 Gas Fireplace | 11
Vertical Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows
Option
V
H + H1
V + V1
With these options,
max. total pipe
length is 30 feet
with min. of 10 feet
total vertical and
max. 8 feet total
horizontal.
Please note min.
1 foot between
90
o
elbows is re-
quired.
A)
0' Min. 2' Max.
2' Min.
B)
1' Min.
2' Max
3' Min.
C)
2' Min.
3' Max
4' Min.
D)
3' Min.
4' Max
6' Min.
E)
4' Min.
5' Max
7' Min.
F)
5' Min.
6' Max
8' Min.
G)
6' Min.
7' Max
9' Min.
H)
7' Min.
8' Max
10' Min.
Restrictor Set 0 - 3" Factory Setting
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows
Horizontal Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows
Option
V
H + H1
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
1' Min. 3' Max.
B)
2' Min. 4' Max.
C)
3' Min. 5' Max.
D)
4' Min. 6' Max.
E)
5' Min. 7' Max.
F)
6' Min.
8' Max.
Restrictor Set 0 - 3" Facto-
ry Setting
Option
V
H
V + V1
H + H1
With these op-
tions, max. total
pipe length is
30 feet with min.
of 12 feet total
vertical and max.
9 feet total hori-
zontal.
Please note min.
1 foot between
90
o
elbows is
required.
A)
0' Min. 1' Max.
1' Min.
2' Max.
B)
1' Min. 2' Max.
3' Min.
3' Max.
C)
2' Min. 2' Max.
5' Min.
4' Max.
D)
3' Min. 2' Max.
7' Min.
5' Max.
E)
4' Min. 3 Max.
9' Min.
6' Max.
F)
5' Min. 4' Max. 10' Min.
7' Max.
G)
6' Min. 5' Max. 11' Min.
8' Max.
H)
7' Min. 6' Max. 12' Min.
9' Max.
Restrictor Set 0 - 3" Factory Setting
U900E-11 Gas Fireplace