10     |  U900E-11 Gas Fireplace

Venting Arrangement for Vertical Terminations

Vertical Venting with One(1) 90

o

 Elbows (1 - 90

o  =  

2 - 45

o

) with straight Vertical and or a maximum offset using  

2 - 90

o

 elbows

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90

o

 elbow, with Rigid 

Pipe Venting Systems

.

Two  45

o  

elbows equal to one 90

o

 elbow.

•   Vent must be supported at offsets.

•   Minimum distance between elbows is 1 ft. (305mm).

•   Maintain clearances to combustibles as listed in the 

"Clearances" section.

•   Horizontal vent must be supported every 3 feet.

•    Firestops are required at each floor level and whenever 

passing through a wall.

•   Must use optional rigid pipe adaptor (Part# 510-994. 

when using rigid pipe vent systems.

• 

Refer to the "Vent Restrictor Position" section for details 
on how to change the vent restrictor from the factory 
setting of Set 0 to Set 1 or Set 2 if required.

U900E-11 Gas Fireplace

Summary of Contents for U900E-11

Page 1: ...High 3 5 W C 0 87 kPa 10 W C 2 48 kPa Manifold Pressure Low 1 6 W C 0 41 kPa 6 4 W C 1 59 kPa Orifice Size Altitude 0 4500 ft 35 DMS 52 DMS Minimum Input Altitude 0 4500 ft 0 1372m 23 500 BTU h 6 89 k...

Page 2: ...ght 20 508mm I Gas Connection Opening Height 1 11 16 43mm J Gas Connection Height 2 11 16 67mm K Gas Connection Inset 1 1 8 29mm L Gas Connection Opening Width 4 11 16 119mm Framing depth measurement...

Page 3: ...nce that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 20 508mm Top of Fireplace Opening B Sidewall on on...

Page 4: ...is used on the mantel and the facing is high quality or the paint may discolour Mantel Leg Clearances Combustible mantel leg clearances as per diagram Note A non combustible mantel may be installed at...

Page 5: ...using a product called Durabond high strength compound for the first coat This product can be found at any hardware store Mud must be cured as per manufacturer s recommendations 6 Prime wall for a se...

Page 6: ...on Combustible materials can be laid against the side and back standoffs and the stove base 4 Non combustible material ie tile slate etc may be brought up to and overlap the unit top and bottom ensuri...

Page 7: ...ical as the installation itself The temperatures around linear gas fireplaces are typically higher than would be acceptable for combustible materials Your Regency Horizon Fireplace is no exception to...

Page 8: ...p adjust and retighten screws 4 Attach both vertical studs 466 126 to the vertical wood studs and secure using 6 screws 2 at bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of the st...

Page 9: ...minations The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510...

Page 10: ...elbows equal to one 90o elbow Vent must be supported at offsets Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent m...

Page 11: ...ne 90o elbow Two 45o elbows Option V H H1 With these options maxi mumtotalpipelengthis30 feetwithminimumof6feet totalverticalandmaximum 8 feet total horizontal Please note minimum 1 footbetween90o elb...

Page 12: ...ver keeptheflexible linerasstraightaspossible avoidunnecessarybending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co lin...

Page 13: ...diagrams show the allowable vertical terminations Restrictor Position Set 0 3 Factory Setting Venting Arrangements Vertical Termination with Co linear Flex System for both Residential Manufactured Hom...

Reviews: