19
Regency I31-3 Gas Fireplace Inbuilt
FAN MAINTENANCE
If your fan requires maintenance or replacement,
access to the fan is through the plate on the rear
wall of the fi rebox.
NOTE: the unit MUST NOT
be operated without the fan access panel
securely in place.
CAUTION: Label all wires prior
to disconnection when servic-
ing controls. Wiring error can
cause improper and dangerous
operation.
Remove the 2 screws holding the
grate in position.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
MAINTENANCE
To remove fan:
1)
Turn the unit off and allow it to cool to room
temperature.
2)
Unplug or disconnect power source to stove.
3)
Remove glass front (see page 10).
4)
Remove
logs.
5)
Remove brick panels.
6)
Remove the Grate by removing the screws
on each side of the grate.
7)
Remove the Burner Tray by removing the
screws on each side of the tray. Push the
tray to the left and lift up.
8)
Remove the 11 screws holding the Access
Panel in place.
9)
Remove the Fan Air Duct by removing 4
screws, 2 per side.
10)
Unplug the black wires from the fan motor
(from inside the stove).
11)
Lift Fan Assembly off of the 2 pins, tip forward
and pull through fi rebox opening.
12)
Disconnect green wire from power cord.
Replacing fan:
Reverse above steps. Hint for pushing fan down
onto pins - rub a bit of dish soap on the grommet
so it will slide more easily onto the pin. Check
to make sure the fan is seated properly on the
pins, this is very important- try to move the fan
back and forth, there should be no noise, if there
is check that the grommets haven't come loose.
PIL
O
T
ON
O
F
F
VENT
HI
LO
HIGH
OFF
LOW
Red
Black
Yellow/Green
Ground
Brown
(Live)
White
Molex
Connector
White
Red
Blue
(Neutral)
Fan Thermodisc
(Normally open)
240V AC
50 HZ
Terminal
Block
Green
Ground
Fan
GLASS GASKET
If the glass gasket requires replacement use
7/8" fl at glass gasket (Part # 936-243) for the
Bay Front and for the Flush Front.