Regency Horizon HZ54EPV Gas Fireplace
5
SAFETY LABEL
This is a copy of the label that accompanies
each HZ54EPV-NG and HZ54EPV-LP Direct
Vent Gas Fireplace. We have printed a copy of
the contents here for your review.
NOTE:
Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
373
373
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
918-940
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed:
Certified for/Certifi e pour:
Tested to:
VENTED GAS FIREPLACE HEATER /
CANADA and U.S.A.
FOYER AU GAZ À ÉVACUATION
é
CAN/CGA-2.17-M91,ANSI Z21.88a-2007/CSA 2.33a-2007
4001172
.
NOT FOR USE WITH SOLID FUEL. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
(
See Instruction Manual for
detailed instructions)
É
É
é
QUIP A L'USINE POUR GAZ PROPANE
CONCU POUR CET POELE: Mod le HZ54EPV-LP
PROPANE GAS: Model HZ54EPV-LP
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR CET POELE: Mod le
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit
minimum selon
D bit
maximum selon
l'altitude
Calorifique
Calorifique
é
é
é
é
é
é
é
HZ54EPV-NG
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit
minimum selon
D bit
maximum selon
l'altitude
Calorifique
Calorifique
é
é
é
é
é
é
D
E
F
A
B
C
Side Walls
A
4” (102mm)
B
40-7/8” (1038mm)
C
20" (508mm)
D
13” (330mm)
E
83" (2108mm)
F
36" (914mm)
Ceiling
Min. Mantel Height
Max. Mantel Depth
Alcove Width
Alcove Depth
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. Listed for use with Power Vent Kit #946-705.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles. Homologué avec terminaison à évacuation mécanique 946-705.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
Min. Supply Pressure
12“WC
(2.98 kpa)
Low Setting Man. Pressure
6.4"WC
(1.59 kpa)
Max. Manifold Pressure
10"WC
(2.49 kpa)
Orifice Size
#49 DMS
Minimum Input
30,000Btu/
Maximum Input
37,000Btu/h (10.84 kW)
(8.79 kW)
0-4500 ft/pi (0-1372 m)
Altitude
Min. Supply Pressure
5“ WC
(1.25 kpa)
Low Setting Man. Pressure
1.6"WC
(0.40 kpa)
Max. Manifold Pressure
3.5"WC
(0.87 kpa)
Orifice Size
#30DMS
Minimum Input
29,000Btu/h
Maximum Input
41,500 Btu/h (12.16 kW)
(8.50 kW)
0-4500 ft/pi (0-1372 m)
Altitude
NATURAL GAS: Model HZ54EPV-NG
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz.