Regency Horizon HZ54EPV Gas Fireplace
25
INSTALLATION
PIPE CONNECTION FROM TERMINAL
TO UNIT
16
) Install cap over terminal with 4 screws.
Note:
Cap may be painted to match building color.
The rigid pipe and rigid pipe adaptor starting from the installed unit
must be installed prior to proceeding.
1)
Install 8" or 16" slip section of pipe over fi nal length of rigid pipe.
17)
Secure fi restop in place with 4 screws (see step 2).
18)
Seal the outer frame with supplied sealant to prevent any water from
entering the building envelope.
2)
Install reducer to the end of 8" slip section.
3)
Connect reducer to Power vent terminal - adjust slip section for fi t.
Secure slip section with screws when optimal fi t is achieved.
Slip section
Reducer
Adjust to fi t
Connect to
Terminal
Caution: Label all wires prior to disconnection when
servicing controls.
Wiring errors can cause improper and dangerous
operation.