32
Regency Horizon HZ54EPV Gas Fireplace
INSTALLATION
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(for mobile home)
Star washer
OPTIONAL FAN WIRING DIAGRAM
WITHOUT PROFLAME GTMF SYSTEM
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
*Speed Control
Switch with
lead wires
(Regency)
Wire Nuts
Wire Nuts
14 AWG wire
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
~
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
*Speed Control
Switch with lead wires
Wire Nuts
14 AWG wire
*Wire Clamp
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
Wire
Black
White
Ground
*Receptacle Box
inside stove
~
*Receptacle
(dedicated use
by unit fan only)
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Thermodisc
Green
Green (Ground)
White (Neutral)
Black (Live)
Black
White
White
(*by others)
(*by
others)
Black
Black
Ground for
mobile home
120 VAC
60HZ
(*by others)
Fan
Rotary Speed
Control
ON
OFF
Fan
(*Supplied
by others
- install
according to
local code)