Regency Horizon HZ54EPV Gas Fireplace
27
INSTALLATION
of
14)
Reverse steps 6-1 to complete installation.
15)
Plug in Power Vent Module to outlet located on the lower left base of
the unit.
10)
Tighten up the strain relief grommets on the outside of the box as
shown below.
11)
Secure the ground wires from each wire bundle (BX cable + power
vent) to the box in the location shown below.
12)
Connect all like colored wires - blue to blue, red to red, white to white
and black to black. Finish wire ends with marettes as shown below.
Ground
13)
Install the cover on the electrical junction box-secure with 2 screws.
9)
Feed wires from the BX cable through into the box.
Caution: Label all wires prior to disconnection when
servicing controls.
Wiring errors can cause improper and dangerous
operation.