13
Regency DVi34L Gas Inbuilt Fireplace
INSTALLATION
Conversion Kit #337-968 from NG to Propane/ULPG Model
DVi34
Conversion Kit #337-968 for NG to Propane/ULPG Model
1
03.25.20
920-237
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
C
onversion Kit Contains:
Qty. Part # Description
1 904-390 LP Burner Orifice #52
1 904-345 ULPG Buner Orifice #53
1 918-728 Orange "PROPANE" Label
1 918-272 Label "Converted to LPG"
1 910-037 Propane Pilot Injector
1 920-237 Instruction Sheet
1)
Shut off the gas supply and unplug
the power cord.
2)
Remove the glass door, logs and
lava rock.
3)
Remove the rear log tray by remov-
ing the 2 screws. (Log tray must be
rotated to clear the burner.)
4)
Remove the grate.
5)
Remove the burner and ensure the
aeration setting is 13 mm open.
6)
Remove burner orifice with a 1/2"
wrench and discard. Use a wrench
to hold on to the elbow behind the
orifice.
Control Box
Cover
Antenna
Jumper Location
16)
Remove the jumper using a plier.
7)
Reinstall new burner orifice Propane
stamped #52 OR ULPG stamped
#53 and tighten
8)
Apply the conversion label "This
unit has been converted to ULPG"
over top of the serial number decal.
12)
Replace the black "NATURAL GAS"
label with either orange "PROPANE"
label OR red "UNIVERSAL LPG"
label.
13)
Carefully pull out the control box.
NOTE: The control box is held in
place with velcro.
14)
Remove the heat shield from the
control box by removing the 2
screws.
15)
Remove the control box cover by
undoing the 3 screws.
Manoeuvre through antenna.
17)
Reverse steps 15, 14, 13, 6, 5, 4, 3
& 2.
Note: Aeration settings do not need
to be adjusted.
Burner Orifice
9)
Pull out the pilot hood by hand.
Pilot
Hood
11)
Put in the new pilot orifice with the
allen key. Then put back the pilot
hood.
Pilot
Hood
removed
10)
Remove the pilot orifice with the
allen key.
Pilot
Orifice
Jumper