FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:
1)
Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.
2)
If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)
Check for proper draft.
CAUTION
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the
responsibility of the manufacturer.
WIRING
Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.
Part #: 909-403 (in-house decal)
Size: 2.875”w x 2”h
Color: Black on white
Created Mar 25/20
909-403
STANDARD WIRING
This unit is polarity sensitive and will
not operate if polarity is incorrect.
INSTALLATION
CAUTION
: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.