DATA BADGE
This is a copy of the label that accompanies each Regency DVi34L
Gas Inbuilt fireplace. We have printed a copy of the contents here for
your review.
DATA BADGE NOTE:
Regency units are constantly being improved.
Check the label on the unit and if there is a difference, the label on the
unit is the correct one.
Part #: 920-243a
Colour: Black on Grey
Size: 100%
Mar. 26/20 - created decal
Apr 30/20 updated MJ/h to kPa for min supply pressure
Electrical: 240VAC 50Hz 1.0 amp
Serial
Number
920-243a
N2134
Regency Gas Fireplace
Gas Type
NG PROPANE ULPG
Model
DVi34LNG DVi34LLP DVi34LULPG
Gas Consumption High
31.7 MJ/h
30.6 MJ/h 26.4 MJ/h
Gas Consumption Low
21.1 MJ/h
25.1 MJ/h
20.9 MJ/h
Min. Supply Pressure
1.13 kPa
2.75 kPa
2.75 kPa
Manifold Pressure High
0.87 kPa 2.51 kPa
2.51 kPa
Manifold Pressure Low
0.40 kPa
1.6 kPa
1.6 kPa
Injector Size
1 x #37
1 x #52
1 x #53
2.64 mm
1.61 mm 1.51 mm
Model
Approval No. AGA 7469 G
SUITABLE ONLY FOR INDOOR INSTALLATION