36
|
City Series CC40E-12
installation
Framing Dimensions (Left Corner)
NOTE:
Framing may be constructed of combustible material (ie. 2 x 4) and does not require steel studs.
Note: A combined minimum of
120 square inches of open area
is required for the convection air
outlet to cool the enclosure. En-
sure clearances for Convection Air
Outlets are met.
See clearances CC40LE/CC40RE
(single sided) in this manual as
there are different methods as to
how this can be achieved.
Framing
Dimensions
Description
CC40LE
A
Framing Height
37-3/8” (949mm)
B*
Framing Width
48-1/4" (1226mm)
C*
Framing Depth
19" (483mm)
D
Unit Base to Top Enclosure (Min.)
63"(1600mm)
G
Vent Centerline Height
56-1/4" (1429mm)
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
Note: This appliance must be in-
stalled on a level and solid surface
such as a plywood floor which must
be the full width and depth of the
appliance.
* The framing depth/width does not take into account dry wall/
wood or similar materials against the back /side wall. The framing
depth will need to change based on the thickness of the material
(example: B - 48 1/4" framing width +1/2" drywall = 48 3/4")
(example: C - 19" framing depth +1/2" drywall = 19 1/2")
*
*
Maximum material dimen
-
sions 2" x 4" for wood
studs in front and side
studs behind can be either
2'' x 4'' or 2'' x 6''.
Note: Wood
header on
edge may be
2'' x 4'' or
2'' x 6''.