12
|
I1500 Regency Wood Insert
|
12
installation
Centre Baffle
Baffle Cover Plate
Baffle Bracket
Note: unit in images may not be identical to the I1500—they depict the process.
1. Open the door.
2. Remove the front secondary air tube with pliers & hammer (hammer not
shown) as shown below.
Note: Some force will need to be used by hammering onto the pliers to enable
to unlock the air tube.
Note: It will be easier to remove the air tubes by removing both the bottom
right base brick and right side wall brick.
10. Install left and right baffle cover plate (installation of left baffle shown below).
Baffle/Catalyst Installation
9. Install the right and left side baffles (right side baffle shown below).
8. Install the center baffle.
Catalyst
4. Pull the flame shield forward and tilt down.
6. Install catalyst and square support installed in previous step into the flue
collar assembly as shown below.
3. Remove locking clip from the front face of the Catalyst assembly by
sliding up and out.
Flame Shield
5. Take your new round catalyst and install it into the square support. See
diagram below.
Catalyst in Square Support
7. Repeat steps 3-4 to reinstall flame shield & locking clip.