background image

42

     | 

F1150 Regency Freestanding Woodstove

warranty

Product Registration and Customer Support: 

Thank you for choosing a Regency Fireplace.  Regency strives to be a world leader in the design, manufacture, and 

marketing of hearth products. To provide the best support for your product, we request that you complete a product 

registration form found on our Web Site under Customer Care within ninety (90) days of purchase. 

For purchases made in 

CANADA or the UNITED STATES

http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx 

For purchases made in AUSTRALIA: 

http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx 

You may also complete the warranty registration form below to register your Regency Fireplace Product and mail and/or 

fax it back to us, and we will register the warranty for you.  It is important you provide us with all the information below in 

order for us to serve you better. 

Warranty Registration Form (or Register online immediately at the above Web Site): 

Warranty Details

 

Serial Number (required): 

Purchase Date (required) (mm/dd/yyyy): 

Product Details

 

Product Model (required): 

Dealer Details

 

Dealer Name (required): 

Dealer Address: 

Dealer Phone #: 

Installer: 

Date Installed (mm/dd/yyyy): 

Your Contact Details

  (required) 

Name: 

Address: 

Phone: 

Email: 

For purchases made in CANADA: 

FPI Fireplace Products 

International Ltd.

 

6988 Venture St. 

Delta, British Columbia 

Canada, V4G 1H4 

Phone: 604-946-5155 

Fax: 

1-866-393-2806

For purchases made in the UNITED STATES: 

Fireplace Products U.S., Inc.

 

PO Box 2189 PMB 125 

Blaine, WA 

United States, 98231 

Phone: 604-946-5155 

Fax: 

1-866-393-2806

For purchases made in AUSTRALIA: 

Fireplace Products Australia Pty 

Ltd 

1

- 3

 Conquest Way

Hallam, VIC

Australia, 3803

Phone: +61 3 9799 7277 

Fax: +61 3 9799

 

7822 

For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. 
Please feel free to contact your selling dealer if you have any questions about your Regency product. 

Summary of Contents for Cascades F1150

Page 1: ...50 Cascades Series Freestanding Woodstove 12 10 19 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future...

Page 2: ...te this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR O...

Page 3: ...ng Bottom Heat Shield Legs 17 Recommended Heights For Woodstove Flue 18 Optional Outside Air Kit 19 Brick Installation 20 Removing Wooden Handle 21 Glass Installation 21 Wood Door Handle Assembly 22 F...

Page 4: ...E ALSO SUITABLE FOR MOBILE HOME INSTALLATION APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGU COMBUSTIBLE SOLIDE CONVENANT AUSSI POUR INSTALLATION DANS UNE MAISON MOBILE FLOOR PROTECTION PROTECTION DE PLANCHER...

Page 5: ...4 831mm 24 610mm 30 3 8 772mm 12 7 8 326mm 17 3 8 441mm 20 508mm 6 1 2 165mm 7 13 16 199mm 29 11 16 753mm 32 813mm Unit with pedestal Unit with legs Outside Air Dimensions Rear Front 4 9 16 115mm Rea...

Page 6: ...le wall OK double wall chimney the chimney connector must be at least 24 gauge steel Do not use galvanized pipe For Mobile Home installation refertotheMobileHomeinstallationinstructions within this ma...

Page 7: ...rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for ship ping and handling It allows for a hand...

Page 8: ...and tighten the bolts 4 Level the stove by adjusting the levelling bolts in the bottom of each leg 5 Reinstall cover plate if not using ash drawer option 6 Install logo plate onto heat shield by plac...

Page 9: ...is installed as a close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level F1150 withAirmateor RearDeflector A B C D E F 11 279mm 7 178mm...

Page 10: ...USA Beneath the heater and extending to at least 16 405mm beyond the fuel loading side and ash removal opening and at least 8 203mm on the sides and back and under the chimney connector extending 2 51...

Page 11: ...nstallation A combustible floor must be protected by non combustible material like tile concrete board or certified to UL 1618 or as defined by local codes extending beneath the heater and a minimum o...

Page 12: ...to initially try with the minimum required height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof wit...

Page 13: ...kage Have the chimney cleaned before the stove is installed and operated When connect ing the stove through a combustible wall to a masonrychimney specialmethodsareneeded Ensure that an effective vapo...

Page 14: ...ombustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6...

Page 15: ...of exit for a height up to 7ft 2130mm 6 Thechimneyshallbeattacheddirectlytotheroom heater and shall extend at least 3 ft 914mm above the part of the roof through which it passes The top of the chimney...

Page 16: ...re flex to the Mobile Home box 7 Secure pedestal base and Mobile Home Box to firebox as shown in diagram 3 using the screws that were previously removed loosened in step 1 See pedestal instructions Th...

Page 17: ...nking plate to the front of the pedestal with 4 screws Use picture from step 8 16 Install the mandatory outside air kit See Mobile Home Instal lation section in this manual Place unit into its final p...

Page 18: ...0 18 0 22 5 4000 5000 14 0 15 0 16 0 17 5 21 0 18 5 23 0 5000 6000 14 5 15 5 17 0 18 0 21 5 19 0 24 0 6000 7000 15 0 16 0 17 5 18 5 22 5 20 0 25 0 7000 8000 15 5 16 5 18 0 19 0 23 0 20 5 25 5 8000 90...

Page 19: ...fresh air into the pedestal area by using a minimum 4 duct pipe with a mesh grill at the outside termination Outside Air Through Pedestal Rear Remove the blanking plate from the rear of the pedestal a...

Page 20: ...cks were removed at install per the diagram below and place in their correct positions Do not use a grate NOTE The AD brick covers the Ash Dump hole that is used if an Ash Drawer Kit is not installed...

Page 21: ...ws securing the glass retainer Position the glass in the door make sure that the glass gasketing will properly seal your unit and replace the retainer it should rest on the gasket not the glass Tighte...

Page 22: ...r is not creating a tight seal a washer can be removed Recheck door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle s...

Page 23: ...with the stove body Remove the fan bend the bracket closer to the stove and re install the fan The fan is to be operated in the LOW position when burning in the LOW MED LOW heat output setting and on...

Page 24: ...osen off both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector pr...

Page 25: ...he flue baffle It may be easier to complete this procedure if the smoke deflector is removed if already installed see previous page for removal procedure 1 Open the unit door 2 Remove front air tube i...

Page 26: ...t dries Two dry pieces banged together sound hollow wet pieces sound solid and dull Dry wood weighs much less than wet wood Split a piece of wood If the exposed surface feels damp the wood is too wet...

Page 27: ...his is to be expected as thehightemperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a v...

Page 28: ...oid your warranty 6 Do not permit creosote or soot build up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 7 YourRegencystovec...

Page 29: ...CARBON MONOXIDE AND ARE VERY DANGEROUS 14 WARNING Do not operate without either the Ash Plug properly seated or the Ash Dump Plates screwed in place excessive temperatures will result 15 CAUTION Do n...

Page 30: ...sote deposits may build up rapidly Moving parts of your stove require no lubrication 4 A small hot fire is preferable to a large smoul dering one that can deposit creosote within the system 5 The chim...

Page 31: ...the remaining 2 tubes Secondary Air Tubes 5 To reinstall or replace first slide left side of tube into hole on left side air channel Align tab on right side air channel with notch on right hand end of...

Page 32: ...ondary air tubes page 31 vermiculite baffles page 25 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP...

Page 33: ...r on a cold stove Close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gask...

Page 34: ...lass Retainer 15 021 973 Door Handle Assembly Complete 16 948 079BN Hinge Cap Brush Nickel Each 17 948 146 Long Black Handle 18 850 241 Black Door Complete 18 850 243 Black with Nickel Accent Door Com...

Page 35: ...F1150 Regency Freestanding Woodstove 35 parts list 4 2 23 3 8 7 6 24 14 11 13 16 15 12 17 18 22 19 21 25 20 26 Main Assembly...

Page 36: ...at Shield 43 942 110 Ashplug 44 820 249 Ashplug Tool 45 075 079 Blanking Plate N S 905 008 5 16 x 6 Long Hex Head Bolt Each N S 820 468F Metal Washer N S 820 456 Metal Spacer Support Bracket Each part...

Page 37: ...anding Woodstove 37 parts list 6 3 3 4 1 2 7 5 2 1 4 3 6 7 AD Fire bricks Size 1 4 1 4 x 7 2 4 1 2 x 7 3 9 x 4 1 2 4 9 x 2 5 3 1 2 x 4 1 2 AD 6 4 1 4 x 8 7 3 1 2 x 2 1 4 AD Ashdump brick 075 960 F1150...

Page 38: ...38 F1150 Regency Freestanding Woodstove notes...

Page 39: ...azing 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect i...

Page 40: ...ncorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts...

Page 41: ...ental or consequential damages so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additiona...

Page 42: ...order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Detai...

Page 43: ...F1150 Regency Freestanding Woodstove 43 notes...

Page 44: ...44 F1150 Regency Freestanding Woodstove notes...

Page 45: ...F1150 Regency Freestanding Woodstove 45 notes...

Page 46: ...46 F1150 Regency Freestanding Woodstove notes...

Page 47: ...F1150 Regency Freestanding Woodstove 47...

Page 48: ...ealer Name Address _______________________________________________ ___________________________________________________________________ Installer _______________________________________________________...

Reviews: