Regency Bellavista™ B41XTCE-10 Gas Fireplace

  |     

3

 

 

|

 

3

MANUFACTURED MOBILE HOME REQUIREMENTS

INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This Regency

®

 product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards:  

VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH 

ALTITUDES CAN / CGA 2.17-M91.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured 

Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured 

Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local 

codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., 

and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable 

to local codes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with 

the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not 

prohibited by local codes.

This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other 

gases. 

Ensure that structural members are not cut or weakened during installation.

Bellavista  

B41XTCE Video

Bellavista B36XT  

Gas Fireplace Benefits

Summary of Contents for Bellavista B41XTCE-LP10

Page 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire...

Page 2: ... the warmth and charm of a wood fireplace at the flick of a switch The Bellavista B41XTCE has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regen...

Page 3: ...s if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable...

Page 4: ... 90o Elbows 29 Horizontal Terminations Three 3 90o Elbows 29 Venting Arrangements for Vertical Terminations 30 Vertical terminations Three 3 90o Elbows 31 Unit Installation with Horizontal Termination Rigid 32 Unit Installation with Horizontal Termination Flex 33 Unit installation with Vertical Termination 34 Gas Line Installation 34 Pilot Adjustment 35 High Elevation 35 885 S I T Valve Descriptio...

Page 5: ...it is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts For the State of Massachusetts flexible connectors shall not exceed 36 inches in length For the State of Massachusetts the appli ances individual manual shut off must be a t handle type valve The State of Massachusetts requires the insta...

Page 6: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon insp...

Page 7: ... 38 3 8 22 674 46 11 16 25 9 16 16 7 16 32 5 8 38 1 4 36 3 8 26 3 16 3 1 4 49 1 4 11 5 8 7 5 16 1 9 16 1 1 2 35 44 1 4 3 5 8 29 1 8 23 7 16 38 7 16 1185mm 974mm 46 11 16 1185mm 976mm 889mm 738mm 92mm 594mm 649mm 664mm 1251mm 38mm 1123mm 417mm 829mm 185mm 294mm 724mm 39mm 923mm 971mm ...

Page 8: ...s BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149 or ANSI Z223 1 Instal...

Page 9: ...rances section d Framing FinishingRequirements Refer to Framing Finishing section e VentingRequirements Referto Venting section 2 Assemble Top Standoffs and Top Facing Support and Side Nailing Strips Refer to Unit AssemblyPriortoInstallation Section Note Mustbedonebeforeinstallingunitinto place 3 Install vent Refer to Venting sections 4 Makegasconnections Testthepilot Mustbe as per diagram Refer t...

Page 10: ...r space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions B41XTCE Clearance Requirements Horizontal Top 3 76mm Horizontal Side 2 51mm Horizontal Bottom 2 51mm Vertical Vent 2 51mm NOTE A16 deep non combustible hearth pad is recommended for hardwood flooring and carpet Clearance Dimension Measured Fr...

Page 11: ...om top of front facing are shown in the diagram on the right Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantel Clearances B41XTCE A B C D From Top of Fireplace Opening 32 11 16 830mm 25 13 16 656mm 22 1 16 560mm 17 9 16 446mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1...

Page 12: ...in this Area 44 1 4 1124mm 46 11 16 1186mm 3 9 16 91mm 11 5 8 295mm 4 1 8 105mm 6 152mm 50 1 4 1276mm NON COMBUSTIBLE BOARD SUPPLIED W UNIT 9 Side Wall Measured from side of Fireplace Opening 7 4 Mantel leg Mantel leg Allowable mantel leg projection 3 1 1 2 NOTE The 6 x 46 11 16 supplied with the unit is secured directly above the unit as shown above All other non combustible material is supplied ...

Page 13: ...ase Ceiling Top 54 1 2 1384mm S Rear Vent Vent Centerline Height Rear 28 1 2 724mm S Top Vent Vent Centerline Height Top 47 1 2 1207mm Rigid Flex T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 5 127mm V Gas Connection Width 3 1 4 82mm W Non Combustible Top Height 13 1 2 343mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed...

Page 14: ...ing a non combustible finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below 1 2 DRYWALL NON COMBUSTIBLE FACING FOR CLEAN LOOK ie painted finish SUPPLIED BY OTHERS 46 11 16 1186mm 1 2 DRYWALL DO NOT EXTEND DRYWALL ONTO METAL SURFACE OF UNIT WOOD STUD 44 1 4 1124mm 6 152mm NON COMBUSTIBLE BOARD SUPPLIED W UNIT ...

Page 15: ...val and access to the lower panel NOTE Non combustible finishing materials may be of any thickness desired Minimum Clearances for Finishing Materials Trim materials Note All non combustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim o...

Page 16: ... 13mm The top nailing strip is adjustable to 1 2 13mm 2 Bend the required four 4 nailing strips to 90º 3 Attach top nailing strip with one 1 screw located at the back of the nailing strip Adjust to required position flush or back 1 2 and tighten screw Nailing strip for Tile Finish set back 1 2 Nailing strip for Clean Finish set flush with unit Adjustable Top Nailing Strip NAILING STRIPS TOP STANDO...

Page 17: ...door frame 2 From inside the firebox remove the baffle plate by removing 4 screws remove top front screw first Baffle Plate 3 From the inside of the firebox remove the exhaust assembly by remov ing the 10 screws 7 From the outside top of the firebox remove the intake cover plate by removing the 4 1 4 x 1 2 screws 5 From the outside top of the firebox remove top insulation cover plate by removing 2...

Page 18: ...sure all screws are tight but do not over tighten All 4 screws must be used Intake Collar Assembly Exhaust Assembly 8 From the outside top of the firebox completely remove the insulation under the cover plate as shown and discard 9 From the outside back of the firebox locate the insulation deflector and bend completely upwards flat against the back of firebox IMPORTANT If the insulation deflector ...

Page 19: ...x 1 2 screws Ensure all screws are tight but do not over tighten See diagram 2 SET 3 THIS HOLE SETS THE VENT RESTRICTOR AT 1 1 2 SET 2 THIS HOLE SETS THE VENT RESTRICTOR AT 2 1 2 SET 1 THIS HOLE SETS THE VENT RESTRICTOR AT 3 1 2 NO VENT RESTRICTOR Factory setting Baffle Plate Diagram 3 Diagram 1 VENTING INTRODUCTION The B41XTCE uses the balanced flue technology Co Axial system The inner liner vent...

Page 20: ...nter line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway loca...

Page 21: ... Offset Support 58DVA ES N A from FPI 5DT OS N A N A Wall Thimble Black 58DVA WT 5DT WT 5DWT TE 5DE90 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A TE 5DE90B Firestop Spacer 58DVA FS 5DT FS 5DFS N A Trim Plate Black 58DAV WFS 5DT TP 5DCP N A 5 X 8 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not all rigid pipe components are availab...

Page 22: ...ptional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 4DDA must be used in conjunction with FPI Rigid Pipe Adaptor 510 994 Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 5 x 8 Venting For specific instructions on venting components visit t...

Page 23: ...0 2 0 6 4 8 Vertical Height Feet Rigid or Flex 47 1 2 1 2m Horizontal Feet Max 36 0 9m 2 0 6 4 8 2 0 6 4 8 Vertical Height Feet 28 1 2 0 7m Horizontal Feet Max 36 0 9m Vent Restrictor Set 1 Factory Setting No Restrictor Required VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5 X 8 REAR VENTING DEFLECTOR INSTALLATION FOR REAR VENTED HORIZONTAL TERMINATIONS Rear Venting Def...

Page 24: ... a top or rear vent Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from Regency may be used for Flex installations 3 Regency Direct Vent System Flex is only approved for horizontal terminations NOTE If longer runs are required the FPI Direct Vent system Flex 946 616 includes all parts needed to install the B41XTCE with a maximum 10 run FPI Kit Le...

Page 25: ...n Cap Wall Thimble Vinyl Siding Standoff Optional Horizontal Termination A Top Vent No Vertical Rise When venting with a 90 elbow directly off the unit Flex vent or approved Rigid Vent System Max 3 ft horizontal run B Rear Vent w Horizontal Termination Max 3ft horizontal run B A HORIZONTAL TERMINATIONS RIGID PIPE 5 X 8 IMPORTANT Must use Rear Venting Deflector packaged with unit in rear vent horiz...

Page 26: ...6 612 Includes 1 AstroCap XL 946 623 P 1 Rigid Pipe Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 Galvanized Rigid Pipe 58DVA 06 1 8 1 2 Galvanized Pipe Extension 58DVA 08A 1 45º Galvanized Elbow 58DVA E45 1 90ml MillPac 948 128 28 1 2 724mm Placement of the Unit into the Corner Back Top Corner of Unit to Wall 3 Inside Corner out along the Wall 65 1 4 Across ...

Page 27: ...yl siding standoff to create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be usedwithvinylsiding measuretooutsidesurface of wall without siding and add 2 inches When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to...

Page 28: ...Set 1 VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A wall thim...

Page 29: ... Max F 5 Min 7 Max G 6 Min 8 Max No Vent Restrictor Installed Lengths do not include elbow indicated Must use rigid pipe adaptor 770 994 One 90o elbow Two 45o elbows Option V H V V1 H H1 W i t h t h e s e options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Pleasenotemini mum 1 foot be tween 90o elbows is required A 0 Min 1 Max 1 Mi...

Page 30: ...r level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting to 3 1 2 opening 2 1 2 opening and to 1 1 2 opening Note Must use optional flue adapter when using Rigid Pipe Part 770 994 Minimum 8 2 4m Min 47 1 2 1 2m 0 2 4 6 40...

Page 31: ...s 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 0 Min 2 Min 2 Max B 1 Min 3 Min 2 Max C 2 Min 4 Min 3 Max D 3 Min 6 Min 4 Max E 4 Min 7 Min 5 Max F 5 Min 8 Min 6 Max G 6 Min 9 Min 7 Max H 7 Min 10 Min 8 Max No Vent Restrictor Installed Lengths do not include elbow indicated Must use rigid pipe adaptor 7...

Page 32: ...ing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failuretodosomayresult in drafting or performance issues not covered under warranty Silicone red RTV is optional Diagram 2 Horizontal runs of vent must b...

Page 33: ...aking sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which wayis up This will position the termination cap with prope...

Page 34: ...ch square hole Frame the hole as shown in Diagram 2 and install the firestop NOTE Forbestresultsandoptimumperform ance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied toeveryinnerpipeconnec tion Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional 4 Assemble the desired lengths of pipe an...

Page 35: ...rewdriver Note Screw should be snug but do not over tighten HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNaturalGas installations above 4500 ft follow current CAN CGA B149 1 B41XTCE NG10 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 30 Max Input Rating 42 500 Btu h Min Input Rating 30 000 Btu h Supply Pressure min 5 0 w c Manifold P...

Page 36: ...de shown Position the left brick panel in place and secure with the brick panel clip and screw removed from the firebox as shown below 6 Slide the top brick panel under the left or right side panel which ever is installed first right side panel shown here and back brick panel use care not to damage panel Left Panel Right Panel Back Panel Top Panel Back Panel Installed 7 Install the remaining side ...

Page 37: ...d not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty 1 Prior to installation of the reflective panels remove the top panel bracke...

Page 38: ... Tighten the screw Location of hex head screw A B 6 Install left side panel repeat step 4 5 Slide top panel under the top of the back and right side panels as shown below Top panel bracket shown installed with Stainless Steel Panels 7 Carefully position and fit the top bracket in place by ensuring the tabs of the bracket fit into the baffle openings as shown below Push downwards to secure the brac...

Page 39: ...ng pieces A Rear Bottom Right Log B Rear Top Left Log C Right Top Cross Log D Front Log Piece E Left Top Cross Log F Center Right Log G Front Bottom Left Log H Front Bottom Right Log I Center Left Log 902 156 Lava Rocks 902 179 Vermiculite 946 669 Platinum Embers supplied w packaged manual 1 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care do not f...

Page 40: ...wn below 8 Slide the left side of Log G back until it touches the tab on the burner shown below 10 Slide the right side of Log H back until it touches the tab on the burner shown below I G H 9 Place Log H on the right front side of the burner in front of log F Position Log G so it fits into the pin on the burner as shown below There is a notch on the bottom of log H position the log so the notch f...

Page 41: ...n below 13 Position Log B on top of Log A Log B fits into the pin in Log A Ensure Log B sits upright 90 degrees with the left side of the log resting on the notch in Log E See next 2 diagrams 14 Position Log C on top of Log H Log C fits into the pin in Log H as shown below E G E A A B C 15 With Log C in position on Log H assure that Log C contacts the back corner of Log A as shown below C A E B Di...

Page 42: ... Platinum Embers Diagram 19 17 Separate platinum embers and place on the front burner on and around the lava rocks Avoid stacking platinum embers Platinum embers may be placed over burner ports IMPORTANT Do not cover burner ports with lava rocks as this will change the flame pattern 16 Place the lava rocks on the burner in front of the logs as shown below Be careful not to overlap the lava rock an...

Page 43: ...connected IMPORTANT Recommend removing the 4 AA batteries in the SureFire receiver This will avoid battery leakage and power drainage 4 AA Battery pack may be re installed into receiver during power outages 919 063 03 04 2013 1 Plug AC adaptor into a 120V wall outlet or into the 120V receptacle if installed inside the gas fireplace 2 Neatly tuck any loose wires neatly underneath inside the firepla...

Page 44: ...t require a 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power failure the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under a...

Page 45: ...lled 2 Remove the mesh barrier and the standard flush door 3 Remove fan assembly from box locate green ground wire and pull out of fan assembly taking care not to damage or cut wire casing 4 Position the fan base with the motor end towards the rear of the firebox and then slide the fan in towards the rear of the unit Turn the fan housing slightly to the left and make the fan assembly paral lel to ...

Page 46: ...ion WIRING DIAGRAM WITH OPTIONAL FAN SureFire Switch CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges ...

Page 47: ...t installation The neutral wider slot of the polarized receptacle should be at the top A wall mounted switch should be installed to turn the accent lighting on off See wiring diagram in the instruction manual Diagram 1 Remove the left and right screws Diagram 2 Slide burner assembly to the right and then remove 7 Remove the 2 screws securing the rear log tray and lift out Diagram 3 Diagram 3 6 Sli...

Page 48: ...nstall two light diffusers on to the base tray 15 Secure diffusers onto base tray from the backside of the tray with 2 screws 16 Reinstall base tray with light diffusers use caution when installing do not damage the bulb 17 Install amber glass on to light diffusers Note Glass is longer than diffuser for ease of removal 18 Reverse steps 9 1 NOTE The ground wire will need to be pulled back out of th...

Page 49: ...1XTCE 10 Gas Fireplace 49 49 installation 918 864a 08 12 14 3 B41XT ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER AC Adaptor ...

Page 50: ... Diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit see Diagram 2 Diagram 1 To remove the flush door reverse the above steps MESH BARRIER 1 To remove the mesh barrier grasp mesh barrier on both sides from the bot tom Lift up and out slightly to release from bottom magnets and to relea...

Page 51: ...ke on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot FIRST FIRE The first fire in your fireplace is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on Whenfirstoperated theunitwillreleaseanodour caused ...

Page 52: ...If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if using optiona...

Page 53: ...ler service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l in...

Page 54: ...ff the gas valve before cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brushasthelogsarefragileandeasilydamaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner Theglassshouldbecleanedwithagas fireplace glass...

Page 55: ...gram 1 Remove the left and right screws Diagram 2 Slide burner assembly to the right and then remove 7 Remove the 2 screws securing the rear log tray and lift out Diagram 3 Diagram 3 6 Slide the burner assembly to the right to release it from the orifice then lift it out 8 Remove the 2 screws securing the base tray lift base tray up and out Diagram 4a and 4b Diagram 4a Diagram 4b 9 Replace the bul...

Page 56: ... Diagram 4a and 4b Diagram 5 Diagram 4a Diagram 4b Diagram 3 Diagram 7 INSTALLING VALVE 1 Placenewvalvetrayandgasketintoposition 2 Reinstall the 14 hold down screws 3 Connect the EV1 EV2 and ground wires to the appropriate connections on the valve 4 Reinstall the rear log tray 5 Install burner grate assembly 6 Hook up the gas line and check for gas leaks with a soap and water solution or a gas lea...

Page 57: ...Gasket Door Top 10 820 389 Thermodisc Bracket 911 012 Ignition Module 12 948 259 Spring Handle Lever 13 948 025 Spring Door Extension 14 940 383 P Ceramic Glass 15 506 083 Door Frame 16 Outerbox Assembly Part Description 17 Firebox Assembly 18 506 517 Fan Assembly 19 910 215 P Fan Motor 120 Volts 20 911 159 Power Cord 120V 37 Mesh Guard 506 959 Optional Accent Light 910 997 Light Bulb 506 057 Flue...

Page 58: ...055 Valve Tray Plate 10 506 075 Air Deflector 11 380 013 Pilot Holder Extruded 12 911 006 Pilot Assembly NG 911 007 Pilot Assembly LP 911 037 Flame Sensor 911 038 Flame Electrode 910 100 Pilot Orifice NG 910 101 Pilot Orifice LP 911 137 Pilot Clip 911 039 Pilot Hood Part Description 15 506 062 Base Tray 911 012 DFC board 911 013 Valve Wiring Harness 911 032 Remote Wiring Harness 910 432 Pilot Tube...

Page 59: ...Regency Bellavista B41XTCE 10 Gas Fireplace 59 59 notes ...

Page 60: ...60 Regency Bellavista B41XTCE 10 Gas Fireplace 60 notes ...

Page 61: ...Regency Bellavista B41XTCE 10 Gas Fireplace 61 61 notes ...

Page 62: ...62 Regency Bellavista B41XTCE 10 Gas Fireplace 62 notes ...

Page 63: ...r agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the...

Page 64: ...ace Products International Ltd Copyright 2014 FPI Fireplace Products International Ltd All rights reserved Bellavista B41XTCE Video Installer Please complete the following information Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ___...

Reviews: