5.3.3.
Optimisation of the control and monitoring functions
Monitoring features and configuration
For the application-specific adjustment of controller configurations,
ramp functions and application monitoring features, the easiest way is
to use the software application “TopControl”. For further information see
TopControl manual.
Controller adjustment
To optimise the dynamic controller behaviour, using a function engine
(option).Set values with square wave steps can be defined. An external
oscilloscope or the internal scope function can be used to measure the
currents and voltages at the same time while the controller settings
change with the aid of TopControl.
Operation with a square wave engine or the variation of the control
parameters in the boundary area can result in oscillations and, in some
circumstances, place the load connected at risk. During this operation, it
is advisable to monitor both the output voltage and the output current
using an external oscilloscope or the internal scope function.
Saving
Once the optimal settings have been found, they can be permanently
saved using TopControl or using the optional operating panels HMI or
RCU.