4
2.0 QUICK START INSTRUCTION
When power is applied to the VGreen Evo™ motor for the first time it will
automatically run the programmed default schedule. This feature ensures that the
VGreen Evo motor will re-start in the event of a power outage.
Refer to section 4.5 Schedule Set Mode - to view the default operating schedule,
or to set the VGreen Evo at one of the other operating schedules.
3.0 WIRING
SHOCK HAZARD
The VGreen Evo motor must be wired according to the locally adopted version of
the NEC. A licensed, qualified electrician should complete the wiring for this
product. The motor is designed to operate with 230/115 VAC single phase power,
and is equipped with auto-voltage detection.
The VGreen Evo motor is designed to handle a direct wire connection, the wire
insulation should be stripped to a length of approximately 0.33". The terminal
block is capable of handling solid or stranded wire up to 12 AWG in size. The
screw for the mains connections should be properly tightened to a torque value
of 10 in-lb.
UI Button
Connector
Dip
Switches
RS-485
Connector
Mains
Terminals
VGreen Evo™ motor