16
3. Clear pump basket and impeller
– Regularly clear pump basket and impeller
to ensure proper operation of pump filtration system.
4. Clean/Backwash filter
– Regularly clean/backwash filter to ensure proper
operation of pump and filtration system.
8.0 FAULT STATUS, MANUAL RESTART AND POWER OUTAGES
The table below illustrates possible faults that can occur with the VGreen
Evo™
motor. If the VGreen Evo motor does not restart automatically disconnect power
to the motor for approximately 3 minutes, then reapply power to the motor. If
this does not correct the situation, contact your local Pool Service Professional.
In the event of a power outage or if power is cycled, the motor will start
operating at hour one of the previously set schedule.
For example, when installed with a mechanical time clock the off/on trippers will
restart the schedule daily when the on tripper applies power. If you wish to
operate at another schedule or reset the current schedule, refer to section 4.5
Schedule Set Mode
.
# OF
FLASHES
ERROR
CONDITION
ERROR RESET CONDITION
1
Input voltage too high or low
Ensure input voltage is in the
correct range.
2
VGreen Evo motor current
too high
Cycle power to the VGreen Evo
motor.
3
Internal temperature too high
Wait for temperature of the motor
to cool down. Ensure VGreen Evo
motor is clear of obstructions that
limit proper ventilation.
4
VGreen Evo motor stalled
Check pump impeller and VGreen
Evo motor fan for obstructions,
then cycle power to motor.
5
Internal VGreen Evo motor
failure
Cycle power to VGreen Evo
motor. If problem persists,
contact your local pool service
professional.
6
Communication lost
Check low voltage connections
between VGreen Evo motor and
application board (3-wire harness).