9
RESERVOIR ASSEMBL
Y — ARS 3000
- 12 gallon (45.4 liter)
1) Place the reservoir on the floor , open side down, so that the legs are
standing straight up.
2) Install the two caster support assemblies onto the reservoir legs by
inserting the raised steel tabs on the caster support assembly into the
open end of the legs. Securely fasten the caster support assemblies in
place using the four 1⁄4” – 20 x 1⁄2” screws.
3) Install the four black plastic end caps by inser ting an end cap into each
open end of the caster support assembly by hand and then tapping into
place using a mallet.
4) Install the four casters into the holes pr ovided on the caster support
assembly . Tighten securely . T urn reservoir over so that it stands open side
up.
5) Decide if you wish to mount the sight gauge faucet on either the wide
or the narrow face of the reservoir. Install the sight gauge faucet by
placing one rubber washer onto the threaded end of the faucet and
inserting the faucet through the mounting hole in the reservoir. From
inside the reservoir securely tighten in place using the black plastic jam
nut. Inspect to make sure that the sight gauge is straight. Position the
sight gauge retaining ring over the sight gauge and hook it over the
edge of the reser voir.
6) Install the r eservoir plug by putting a rubber washer over the threaded
end of the plug and inserting it into the remaining hole in the reser voir.
From inside the reser voir, tighten into place using a black plastic jam
nut. Do not over-tighten jam nuts. Avoid squeezing out rubber washer .
7) Install the pr epared post carbon filter cup by following the instructions
on page 11.
Note:
If installing an AP2000 W3000 Series Pump Box, please refer to the
Pump Box Use and Care Guide (included with your Pump Box) in or der to
complete the assembly of the reservoir. The demand Pump Box is an optional
addition to your system.