4
SPR 0.1PA
It is recommended to have
after-guarantee service
performed by the service department of
the production plant, or by a contracted service centre. Serviceman makes the record about service
mission after warranty actions and sends it to the production company.
1.7 Operation conditions
1.7.1 Product location and operation position
•
The assembly and operation of electric actuators in standard make can be on covered places of
industrial objects without the regulation of temperature, humidity and with protection against direct
exposure of climate influence (e.g. direct sun shine).
•
Electric actuators must be placed with access to the manual control wheel, to the button for
disengaging the transmission, to the cover of control box, to control box, to
cable glands
.
•
Installation and operation of actuators is possible in either position. Common position is the one
with vertical position of exit part axis and control box above. Avoid to arrange the electric actuator
under the armature if possible.
•
Operating angle adjusted by stop ends must be greater than angle set electronically to the
actuator. The stop ends are used only for position setting by manual adjusting of the
actuator. Use the stop ends in motor-operated operation of actuator is inadmissible!
Warning:
Actuator installed on the open place must be protected against a direct climate effects by
shelter, mainly from sunshine.
In applications placed in an ambient of a relative moisture above 80%, in external ambient under
shed, it is necessary to change the preset thermostat temperature +25°C to +70°C by a PC
and program to prevent switching off the heating resistor.
1.7.2 Operation Environment
According to standard IEC 60 721-2-1:
EA have to resist external effects and operate reliably:
in climatic conditions for the group / type of climate:
- version
„standard“
-
for climate group
Restricted
(R) + /Warm temperature (WT), Warm Dry
(WDr), Mild Warm Dry (MWDr) and Extremely Warm Dry (EWDr) with
corrosion resistance C3 resp. C4 (EN ISO 12944-2)
Besides this according to GOST 15 150- 69:
- version
„tropical“
meet with
Dry and
Damp tropics
, for climate types Warm Temperate
(WT), Warm Dry (WDr), Mild Warm Dry (MWDr), Extremely Warm Dry
(EWDr), Warm Damp (WDa) and Warm Damp Equable (WDaE) with
corrosion resistance C3 (EN ISO 12944-2)
Category of location
- versions
“standard“
and
“tropical”
are intended for location
under the
shelter (category 2)
Atmosphere type
-
versions
“standard“
and
“tropical”
are intended for location in atmosphere
type II
industrial
Summary of Contents for SPR 0.1PA
Page 9: ...SPR 0 1PA 7 1 7 2 Fig 1 5 4 3 8...
Page 29: ...SPR 0 1PA 27 6 Accessories 6 1 Wiring diagrams...
Page 32: ...30 SPR 0 1PA 6 2 Dimensional drawings...
Page 33: ...SPR 0 1PA 31...
Page 34: ...32 SPR 0 1PA...
Page 35: ...SPR 0 1PA 33...
Page 36: ...34 SPR 0 1PA...
Page 37: ...SPR 0 1PA 35...
Page 38: ...36 SPR 0 1PA...