Reflex Reflexomat Basic RS 90 / 1 Operating Manual Download Page 5

 

Technical data 

 

 

 

Reflexomat Basic — 20.09.2020 - Rev. A 

 

English  — 5 

 

 

Note! 
Additional equipment for topping up water, see chapter 4.6 "Optional 
equipment and accessories" o
n page 5 . 

 

4.5

 

Scope of delivery 

The scope of delivery is described in the shipping document and the content is 
shown on the packaging.  
Immediately after receipt of the goods, please check the shipment for 
completeness and damage. Please notify us immediately of any transport 
damage. 

 

Basic pressure-maintaining equipment: 
• 

One primary vessel up to 600 litres and one compact control unit. 

• 

"LIS" pressure load cell for level sensing. 

 

4.6

 

Optional equipment and accessories 

• 

Secondary vessels with connection sets for the primary vessel. 

• 

For make-up with water 
–  

Make-up without pump: 
• 

Solenoid "Fillvalve" with ball valve and Reflex Fillset for make-
up with drinking water. 

–  

Make-up with pump: 
• 

Reflex Fillcontrol Auto, with integrated pump and a system 
separation vessel or Auto Compact 

• 

For make-up and degassing with water: 
–  

Reflex Servitec S 

–  

Reflex Servitec 35- 95 

• 

Fillset for make-up with drinking water. 
– 

With integrated system separator, water meter, dirt trap and locking 
mechanisms for the "WC" make-up line. 

• 

Fillset Impulse with FQIRA+ contact water meter for make-up with 
drinking water. 

• 

Fillsoft for softening or desalination of the make-up water from the 
drinking water network. 
–  

Fillsoft is installed between Fillset and the device. The device 
controller evaluates the make-up quantities and signals the required 
replacement of the softening cartridges. 

• 

Optional expansions for Reflex controllers: 
– 

I/O module for standard communication. 

–  

Master-Slave-Connect for master controllers for maximum 10 
devices. 

–  

Bus modules:  
• 

Profibus DP 

• 

Ethernet 

• 

Diaphragm rupture monitor 

 

 

Note! 
Separate operating instructions are supplied with accessories. 

 

5

 

Technical data 

5.1

 

Control unit 

Permissible ambient temperature 

0 – 45 °C 

Degree of protection 

IP 54 

Noise level 

72 dB 

Electric output 

750 W 

Power supply 

230 V / 50 Hz 

Fusing 

3 A 

Electrical voltage control unit 

230 V / 2 A 

Number of RS-485 interfaces 

Weight 

21 kg 

Permissible operating temperature 

70 °C 

Permissible flow temperature 

120 °C 

I/O module 

optional 

 

5.2

 

Tanks 

 

  Primary vessel 

Secondary vessel 

 

 

 

Note! 
The following values apply for all vessels: 

 

–  

Operating pressure: 

–  

Connection: 

6 bar 
R1" 

 

Type 

Diameter Ø 

"D" (mm) 

Weight 

(kg) 

Height "H" 

(mm) 

Height "h" 

(mm) 

Height "h1" 

(mm) 

200 

634 

37 

970 

115 

155 

300 

634 

54 

1270 

115 

155 

400 

740 

65 

1255 

100 

140 

500 

740 

78 

1475 

100 

140 

600 

740 

94 

1720 

100 

140 

 

6

 

Installation 

 DANGER 

 

Risk of serious injury or death due to electric shock. 
If live parts are touched, there is risk of life-threatening injuries. 
• 

Ensure that the system is voltage-free before installing the device. 

• 

Ensure that the system is secured and cannot be reactivated by other 
persons. 

• 

Ensure that installation work for the electric connection of the device is 
carried out by an electrician, and in compliance with electrical 
engineering regulations. 

 
 

 

 CAUTION 

 

Risk of injury due to pressurised liquid 
If installation, removal or maintenance work is not carried out correctly, there 
is a risk of burns and other injuries at the connection points, if pressurised 
hot water or hot steam suddenly escapes. 
• 

Ensure proper installation, removal or maintenance work. 

• 

Ensure that the system is de-pressurised before performing installation, 
removal or maintenance work at the connection points. 

 
 

 

 CAUTION 

 

Risk of burns on hot surfaces 
Hot surfaces in heating systems can cause burns to the skin. 
• 

Wear protective gloves. 

• 

Please place appropriate warning signs in the vicinity of the device. 

 

 CAUTION 

 

Risk of injury due to falls or bumps 
Bruising from falls or bumps on system components during installation. 
• 

Wear personal protective equipment (helmet, protective clothing, 
gloves, safety boots). 

 

 

 WARNING 

 

Risk of injury due to heavy weight 
The devices are heavy. Consequently, there is a risk of physical injury and 
accidents. 
• 

Use suitable lifting equipment for transportation and installation. 

 

Summary of Contents for Reflexomat Basic RS 90 / 1

Page 1: ...20 09 2020 Rev A Reflexomat Basic GB Operating manual Original operating manual Reflexomat RS 90 1 mounted Reflexomat external air...

Page 2: ...5 Fitting the level sensor 8 6 4 Make up and degassing variants 8 6 4 1 Function 8 6 5 Electrical connection 9 6 5 1 Terminal diagram 9 6 5 2 RS 485 interface 9 6 6 Installation and commissioning cert...

Page 3: ...observe the safety information can result in death or severe irreversible injuries CAUTION Damage to health The sign in combination with the signal word Caution indicates danger failure to observe th...

Page 4: ...or SV Safety valve PV Solenoid valve LIS Pressure load cell EC Expansion pipe Expansion vessels One primary vessel and multiple optional secondary vessels may be connected A membrane separates the ves...

Page 5: ...otection IP 54 Noise level 72 dB Electric output 750 W Power supply 230 V 50 Hz Fusing 3 A Electrical voltage control unit 230 V 2 A Number of RS 485 interfaces 1 Weight 21 kg Permissible operating te...

Page 6: ...eing stressed or strained If necessary provide support structures for the pipes or equipment For installation proceed as follows Position the device Complete the primary tank and the optional secondar...

Page 7: ...cables are factory installed on the primary vessel The cables between the primary vessel and the control unit are pre installed Subsequently install the level sensor at the primary vessel see chapter...

Page 8: ...ontroller s customer menu the external make up is activated 6 4 1 1 Make up without pump Reflexomat Basic with solenoid valve and ball valve 1 Reflexomat Basic WC Make up pipe 2 Solenoid valve Fillval...

Page 9: ...ke up request Not used with the Reflexomat 17 Make up 230 V 18 Make up 230 V 19 PE shield Level analogue input Display at the controller Activation of the make up Factory prepared sensor plug must be...

Page 10: ...n in extreme cases Note Avoid dropping below the P0 minimum operating pressure Vacuum vaporisation and cavitation are thus excluded 7 3 Modifying the controller s start routine Note During commissioni...

Page 11: ...e up pressure at least 1 3 bar above the set minimum pressure P0 Without automatic make up Use the discharge ports or the facility system to manually fill the individual tank to approximately 30 of th...

Page 12: ...ey marked menu items must be reviewed during commissioning Press Manual to switch to manual operation Press Menu to display the first main menu option Customer menu Indication on the display Meaning C...

Page 13: ...oftening used and the specified hardness reduction Fillsoft I soft water capacity 6000 hardness red l Fillsoft II soft water capacity 12000 hardness red l Enter the value in the controller Consult the...

Page 14: ...ed Note Floating contacts setting in the Customer menu see chapter 9 2 Configuring settings in the controller on page 12 ER Code Alarm Floating contact Causes Remedy Alarm reset 01 Minimum pressure YE...

Page 15: ...een option card and controller faulty Option card defective Inform Reflex Customer Service 31 EEPROM defective YES EEPROM defective Internal calculation error Inform Reflex Customer Service Quit 32 Un...

Page 16: ...ended closing Checking Insufficient water Off 14 Check the displayed value for the Insufficient water OFF filling level message Insufficient water Off is displayed at the controller at a minimum filli...

Page 17: ...ified by the operating company based on a safety evaluation taking into consideration the actual operating conditions experience with the mode of operation and charging material and the applicable nat...

Page 18: ...Installation and commissioning certificate This device has been installed and commissioned in accordance with the instructions provided in the operating manual The settings in the controller match th...

Page 19: ...SI2041enA 11 20 Reflex Winkelmann GmbH Gersteinstra e 19 59227 Ahlen Germany 49 0 2382 7069 0 49 0 2382 7069 9546 www reflex winkelmann com...