Once the protected area has been occupied, the relay outputs are de-
activated. The sequence described above must be repeated in order to
re-activate these.
The RESTART command is active with a voltage of 24 Vdc.
The minimum duration of the command is 300 ms.
Figure 2
CONNECTION OF EXTERNAL CONTACTORS K1 and K2
Control of external contactors K1/K2 can be activated in both operating
modes. If this control is to be used, the set of normally closed and
normally open ed contacts of the external contactors must be connected
to terminal 13 of the interface (figures 3 and 4).
Figure 3
Automatic functioning with K1/K2 relays
**
CONNECT INPUTS 8-9-11 TO +24Vdc AND INPUT 12 TO 0Vdc
IF NOT USED
*
USE SUITABLE ANTI-DISTURBANCE DEVICE
**
CONNECT INPUTS 8-9-11 TO +24Vdc AND INPUT 12 TO 0Vdc
IF NOT USED
USE CONTACTS