IRRIGATION  USE  -  MANDATORY  REQUIREMENTS  FOR  ALL  INSTALLATIONS:   

For  any 

installation  of  pumps  supplying  irrigation,  you  must  fit  an  18L  or  larger  pressure  tank. 

Set tank air pressure: RPS036 set air pressure to 250kPa, RPS050 set air pressure to 350kPa 

 
 

17)

 

IMPORTANT NOTICE RE THE STOPPING FUNCTION: 

In some situations the pump will cycle 

a few times after each use. THIS IS NOT A WARRANTY FAULT,

 it is a normal function of 

the  internal  pump  controller  releasing  excess  pressure  when  there  is  some  “bounce”  or 
“give”  in  the  pipework  or  connected  fixtures  –

  it  is  often  caused  by  toilet  cisterns  or  a 

short discharge pipe or flex in pipes. It is not a fault with the pump.  If the owner does not 
want this to occur, install a 2L or larger Pressure Tank, set the tank air pressure: RPS036 
set air pressure to 250kPa, RPS050 set air pressure to 350kPa.  

 

 

18)

 

IF THE PUMP BLEEDS OUT OF THE TOP After startup, the pump may bleed water out of the 
top of the pump 

 this is NOT a fault, it is the normal operation of the pump.   

 

19)

 

Some air can be pumped when the tank is low in water

 

 this is not a fault it is normal 

operation. 

 

20)

 

NO RCD/SAFETY SWITCH?  DO 

NOT

 INSTALL PUMPS!!

 

 
 
FURTHER INFORMATION FOR THE INSTALLER 

 

21)

 

Try to minimise the amount of bends in the delivery pipe.  Pipes of insufficient diameter connected to the 
pump  will  severely  restrict  the  performance  of  the  pump,  cause  the  pump  to  use  more  electricity,  and

 

may  cause  the  pump  to  cycle  on/off  frequently

this  is  not  covered

 

by  warranty  as  it  is  caused  by  the 

installer.

  If the user requires the best possible pressure from the pump, the recommendation is for the 

delivery pipe to be 25mm ID for the majority of the pipeline.  

22)

 

IRRIGATION USE TANK PRESSURE SETTING:

  Air pressure must be set at 70% of maximum pump pressure 

 set the tank air pressure: RPS036 set air pressure to 250kPa, RPS050 set air pressure to 350kPa.   The 

Pressure 

Tank is simply fitted to the discharge pipework with a “tee”, anywhere between the pump and 

the first point of discharge. 

23)

 

During installing or servicing 

disconnect the pump from the power supply. 

24)

 

Ball-valves  or  gate-valves  must  be fitted on the  discharge,  and  the  Town-water backup supply  where 
fitted.

 An additional Check-valve must be fitted outside of the tank (not on the pump) where it is used 

with  a  Town-water  backup  system,  but only  if  the  Town-Water  backup system  does  not  have  a  built-in 
check-valve on the Rainwater connection. This instruction is a condition of warranty; all warranty is void if 
this  instruction  is  not  followed.    The  pump  must  be  installed  to  comply  with  applicable  Plumbing 
Regulations. 

25)

 

Do not remove the base off the pump

 as this will then cause it to take in solids or sludge which will lead 

to reduced performance and ultimately, failure, which is not covered by the warranty. This pump is not to 
be used as your sole water supply. For critical applications where loss of water supply could cause serious 
consequences,  use  a  DUAL  PUMP  System  so  you  have  a  back  up  water  supply  or  use  a  TOWN-WATER 
BACK-UP SYSTEM.  This pump is not designed for Fire Fighting purposes. 

26)

 

IMPORTANT:

 This pump MUST NOT be installed in any manner that if it were to fail that it would cause 

damage or loss to property or persons. It MUST be installed in a well-ventilated and drained area.  

27)

 

DO NOT lower or lift the pump using the power cable 

 use nylon rope to lower or lift the pump in and 

out of the tank.   

Summary of Contents for RPS036

Page 1: ...Page 1 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 5: ...d follow the instructions which are to be read in conjunction with the diagrams on the earlier pages Ensure all installations are in compliance with any relevant Australian Standards this is the insta...

Page 6: ...repair or servicing if the rainwater tank is installed under eaves or under a deck or any other structure ensure the pump can be easily removed 10 For underground tanks the installation must be design...

Page 7: ...the pump the recommendation is for the delivery pipe to be 25mm ID for the majority of the pipeline 22 IRRIGATION USE TANK PRESSURE SETTING Air pressure must be set at 70 of maximum pump pressure set...

Page 8: ...ressure Tank somewhere between the pump and the first point of discharge suggested pressure setting for the tank is 150kPa 31 NO WATER FUNCTION The pump will stop automatically if the tank is empty ne...

Page 9: ...can be annoying to the residents In the early morning turn it off on again after 1 minute and it will reset itself so it does the checking in daylight hours h You can reset the function back to the b...

Page 10: ...arge pipework does the pump stop the leak is further down the line if not then check toilets etc the only sure way to check toilet cisterns is to turn them off at the stopcock which is usually under t...

Page 11: ...ording to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the...

Page 12: ...for servicing or repairs Warranty replacement does not normally include costs of removal and re installation as we have no control over the method of installation 8 Before installing or servicing dis...

Reviews: