Reefe RPS036 Instruction Manual & Warranty Download Page 6

Page 

6  

Ascento Group Australia P: 1800 807 604 E: [email protected]       

 

 

 
4)

 

DO NOT install it in such a manner that it would require a person to get inside the tank to 
remove/repair it.   
 

5)

 

You MUST use 25mm or larger POLY or PVC pipe

 connected to the discharge of the pump. 

DO  NOT  CONNECT  COPPER  or  GALV  PIPE  or  less  than  25mm  ID  POLY/PVC  PIPE  to  this 
pump. 
 

6)

 

VERY  IMPORTANT: 

Ensure  that  the  connection  to  the  outlet  of  the  pump  is  robust  and 

sealed VERY well.

 Use 15 wraps of thread-seal tape on the male thread.  DO NOT USE glue 

unless you are CERTAIN that you will not drip glue inside the pump.   

 
7)

 

Glue or other substances dripped inside the pump voids warranty

. Do NOT fit threaded 

fitting to the pump then glue pipe to that fitting as glue will drip inside the pump.  Glue the 
fitting and allow it to dry BEFORE attaching the threaded fitting to the pump.  NOTE: If the 
fitting leaks, it will cause cycling of the pump, this is not warranty 

 

this is the installer’s

 

responsibility.   

  
8)

 

Ensure  that  the  pump  will  not  knock  against  the  side  of  the  tank  during  start-up,  or 
operation or stopping.    

 

9)

 

No  electrical  appliance  lasts  forever  -

  the  pump  must  be  easily  accessible  for  repair  or 

servicing  -  if  the  rainwater  tank  is  installed  under  eaves,  or  under  a  deck  or  any  other 
structure, ensure the pump can be easily removed. 

 
10)

 

For 

underground tanks

, the installation must be designed and constructed to allow easy 

access,  for  servicing  and  repairs  to  the  pump.    In  the  unlikely  event  of  pump  failure, 
warranty does not include costs of digging up gardens and re-running electrical cables, etc. 

 

11)

 

If  the  pump  has  a  float  switch,  ensure  it  CANNOT  get  stuck

  on  the  side  of  the  tank  or 

under baffles or similar - warranty service does not cover this situation. FOR PUMPS WITH 
FLOATS:  The water level will need to be 0.6m to 1.2m high inside the tank, for the pump 
to start.   

 

12)

 

An Isolation valve must be fitted (ball-valve or gate-valve) in the discharge pipework 

 
13)

 

A  Barrel-Union  must  be  fitted  external  of  the  tank  to  allow  easy  servicing  of  the  pump, 
install it after the elbow to avoid it twisting loose from the pump starting & stopping. 

 

14)

 

It is the INSTALLERS responsibility to check the pumps operation prior to leaving the site 
CHECK ALL CONNECTIONS:  Ensure all fittings and joints are watertight and airtight.  Leaks 
will cause the pump to cycle on & off continuously, this is not a fault of the pump. 

 

15)

 

All  Electrical  Wiring  &  Power  Outlet  &  Cable  protection  must  be  in  accordance  with 
applicable Australian Standards. We recommend a separate circuit.  

 

Summary of Contents for RPS036

Page 1: ...Page 1 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 5: ...d follow the instructions which are to be read in conjunction with the diagrams on the earlier pages Ensure all installations are in compliance with any relevant Australian Standards this is the insta...

Page 6: ...repair or servicing if the rainwater tank is installed under eaves or under a deck or any other structure ensure the pump can be easily removed 10 For underground tanks the installation must be design...

Page 7: ...the pump the recommendation is for the delivery pipe to be 25mm ID for the majority of the pipeline 22 IRRIGATION USE TANK PRESSURE SETTING Air pressure must be set at 70 of maximum pump pressure set...

Page 8: ...ressure Tank somewhere between the pump and the first point of discharge suggested pressure setting for the tank is 150kPa 31 NO WATER FUNCTION The pump will stop automatically if the tank is empty ne...

Page 9: ...can be annoying to the residents In the early morning turn it off on again after 1 minute and it will reset itself so it does the checking in daylight hours h You can reset the function back to the b...

Page 10: ...arge pipework does the pump stop the leak is further down the line if not then check toilets etc the only sure way to check toilet cisterns is to turn them off at the stopcock which is usually under t...

Page 11: ...ording to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the...

Page 12: ...for servicing or repairs Warranty replacement does not normally include costs of removal and re installation as we have no control over the method of installation 8 Before installing or servicing dis...