Reefe RPS036 Instruction Manual & Warranty Download Page 5

Page 

5  

Ascento Group Australia P: 1800 807 604 E: [email protected]       

 

 

 

INSTRUCTION MANUAL & WARRANTY 

 REEFE RPS036 & RPS050 

Multistage Submersible Pump 

** Please leave this guide in a safe place for the owner ** 

 

 

PERFORMANCE DATA 

 

CODE  MODEL 

POWER 

RATED 

MAXIMUM 

FLOAT 

SWITCH 

CABLE 

LENGTH 

OUTLET 

(mm) 

SIZE L x W x H 

(mm) 

AMPS 

P1 

(kW) 

P2 

(kW) 

FLOW 

(L/min) 

HEAD 

(m) 

FLOW 

(L/min) 

HEAD 

(m) 

12178  RPS036 

3.5 

0.8 

0.45 

40 

28 

100 

37m 

 - 

10m 

25FBSP 

150 x 160 x 650 

12185  RPS050 

4.6 

1.2 

0.75 

50 

38 

100  

50m 

 - 

10m 

25FBSP 

150 x 160 x 800 

13588  RPS036F  3.5 

0.8 

0.45 

40 

28 

100  

37m 

Yes 

10m 

25FBSP 

150 x 160 x 650 

15582  RPS050F  4.6 

1.2 

0.75 

50 

38 

100  

50m 

Yes 

10m 

25FBSP 

150 x 160 x 800 

NOTE:  Performance data quoted is generally from test data and does not take into account factors in the installation such as loss of pressure and flow due to pipework & pipe-fittings & valves. 

 

INSTALLATION GUIDELINES 

Please  read  and  follow  the  instructions  which  are  to  be  read  in  conjunction  with  the  diagrams  on  the  earlier  pages.  Ensure  all 
installations  are  in  compliance  with  any  relevant  Australian  Standards,  this  is  the  installers  responsibly.    Warranty  covers 
manufacturing defects of the pump; it does not include faults in the installation. Note that all warranty is voided if the instructions 
are not followed. Use for CLEAN FRESH WATER only.  

IMPORTANT INSTALLATION & WARRANTY 

CONDITIONS 

1)

 

A “First

-flush-

diverter” or similar device must be installed, and /or a filter screen through 

which  all  the  incoming  water  passes  before  entering  the  tank,

  to  prevent  debris  from 

entering the tank.   
 

2)

 

Warning: when lowering Pump into Rainwater Tank:

 Use the rope supplied to lower the 

pump into the tank. DO NOT USE THE POWER CABLE. Using the power cable will lead to 
pump failure which will not be covered by warranty, all costs will be borne by the installer. 
 

3)

 

Install the pump UPRIGHT in the tank. 

The length of the pump must be vertical, it must 

not be on an angle off vertical, it must not be horizontal.   

Summary of Contents for RPS036

Page 1: ...Page 1 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au...

Page 5: ...d follow the instructions which are to be read in conjunction with the diagrams on the earlier pages Ensure all installations are in compliance with any relevant Australian Standards this is the insta...

Page 6: ...repair or servicing if the rainwater tank is installed under eaves or under a deck or any other structure ensure the pump can be easily removed 10 For underground tanks the installation must be design...

Page 7: ...the pump the recommendation is for the delivery pipe to be 25mm ID for the majority of the pipeline 22 IRRIGATION USE TANK PRESSURE SETTING Air pressure must be set at 70 of maximum pump pressure set...

Page 8: ...ressure Tank somewhere between the pump and the first point of discharge suggested pressure setting for the tank is 150kPa 31 NO WATER FUNCTION The pump will stop automatically if the tank is empty ne...

Page 9: ...can be annoying to the residents In the early morning turn it off on again after 1 minute and it will reset itself so it does the checking in daylight hours h You can reset the function back to the b...

Page 10: ...arge pipework does the pump stop the leak is further down the line if not then check toilets etc the only sure way to check toilet cisterns is to turn them off at the stopcock which is usually under t...

Page 11: ...ording to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected All swarf has been removed from the tank after cutting openings etc Barrel Unions are fitted on the...

Page 12: ...for servicing or repairs Warranty replacement does not normally include costs of removal and re installation as we have no control over the method of installation 8 Before installing or servicing dis...

Reviews: