background image

13

Battery Replacement

When the low battery icon appears on the LCD display, you will need to 
replace the batteries. Remove the battery cover using a Phillips head 
screwdriver, insert 4 x new "AA" batteries and secure the cover.

Accessories and Replacement Parts

•  CA-05A 

Soft Carrying Case

Don't see your part listed here? For a complete list of all accessories and 
replacement parts visit your product page on www.reedinstruments.com.

Product Care

To keep your instrument in good working order we recommend the following:
•  Store your product in a clean, dry place.
•  Change the battery as needed. 
•  If your instrument isn't being used for a period of one month or longer 

please remove the battery.

•  Clean your product and accessories with biodegradable cleaner. Do not 

spray the cleaner directly on the instrument. Use on external parts only.

Product Warranty

REED Instruments guarantees this instrument to be free of defects in 
material or workmanship for a period of one (1) year from date of shipment. 
During the warranty period, REED Instruments will repair or replace, at no 
charge, products or parts of a product that proves to be defective because 
of improper material or workmanship, under normal use and maintenance. 
REED Instruments total liability is limited to repair or replacement of the 
product. REED Instruments shall not be liable for damages to goods, 
property, or persons due to improper use or through attempts to utilize the 
instrument under conditions which exceed the designed capabilities. In 
order to begin the warranty service process, please contact us by phone at 
1-877-849-2127 or by email at [email protected] to discuss the 
claim and determine the appropriate steps to process the warranty.

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R8008

Page 1: ...Radiation Detector Instruction Manual R8008 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...ccumulation Time 8 Pulse Counting 9 Data Storage 9 10 Bluetooth Recording Mode 10 Battery Life Indicator 10 Setup Menu 10 12 Set Date 10 Set Time 11 Setting Alarm Threshold 11 Enabling Disabling Pulse...

Page 3: ...acing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Detects Alpha Beta Gamma and X ra...

Page 4: ...gital Bargraph Indicator Yes Adjustable Alarms Yes Audible Visual Indicators Average Time Function 2 to 120 seconds Natural Environment Reading 0 to 0 2 Sv h Datalogging Capabilities Yes Real Time Clo...

Page 5: ...on 9 ESC Button 10 Battery Up Arrow 11 Dose Button 12 Pulse Button Display Description 1 Boot Nuclear Radiation Measuring Icon 2 Date Time Icon 3 Setup Menu Indicators 4 Measuring Function Indicators...

Page 6: ...horized distributor or customer service at info reedinstruments com or 1 877 849 2127 Operating Instructions The R8008 is intended to detect the radiation dose rate of and X rays radiated from an obje...

Page 7: ...or deactivate the LCD backlight The backlight will automatically turn off after 1 minute Unit Conversion for Dose Rate When the meter is powered ON the default unit of measurement is set to Sv h Pres...

Page 8: ...digit 5 When ready press the and arrows to adjust the flashing digit 6 Press the button to confirm your selection and proceed to the next digit 7 When the last digit has been selected and confirmed t...

Page 9: ...the set time refer to Setting Dose Accumulation Time for details 5 Throughout the measurement process the icon will blink on the LCD display 6 The meter will beep when the set time is up and the cumu...

Page 10: ...meter s battery status press the button 2 The meter will now indicate the remaining internal battery voltage 3 Press the ESC button to resume normal operation Setup Menu You can adjust the following...

Page 11: ...e Alarm Threshold Setup screen 4 Make sure to start with the leftmost digit 5 To toggle between digits press the enter button to move to the next digit or press the ESC button to return to the previou...

Page 12: ...setup screen 4 Make sure to start with the leftmost digit 5 To toggle between digits press the button to move to the next digit or press the ESC button to return to the previous digit 6 When ready pr...

Page 13: ...rument Use on external parts only Product Warranty REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one 1 year from date of shipment During...

Page 14: ...ED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets p...

Page 15: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 16: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: