12
Non-Contact AC Voltage Measurements
1. Set the rotary function switch any measurement position.
2. Place the tip of the meter to the hot conductor under test or the hot
side of the electrical outlet.
3. If AC voltage is present, the detector will light up.
Note:
The conductors in electrical cord sets are often twisted. For best
results, rub the probe tip along a length of the cord to assure placing
the tip in close proximity to the live conductor. The detector is designed
with high sensitivity. Static electricity or other sources of energy may
randomly trip the sensor.
Auto Power Off
To preserve battery life, the meter is programmed to turn off after approx.
30 minutes of inactivity.
Data Hold
1. While taking a measurement, press the
HOLD
button to freeze the
current reading on the display.
2. While in this mode a "HOLD" symbol will appear on the LCD.
3. Press the
HOLD
button again to resume normal operation.
Relative Mode
1. Press the
REL
button to enter relative mode which will zero the
reading and create a reference point.
2. REL will appear on the LCD display. Future readings will display a
value that is the difference between the actual reading and the stored
relative reading.
Note:
While in Relative mode, auto ranging is disabled and measurements
are limited to the range that is active when the
REL
button was pressed.
3. Press the
REL
button to exit relative mode and resume
normal operation.
Note:
Relative mode does not function in Frequency or Duty Cycle mode.