12

Non-Contact AC Voltage Measurements

1.  Set the rotary function switch any measurement position.
2.  Place the tip of the meter to the hot conductor under test or the hot 

side of the electrical outlet.

3.  If AC voltage is present, the detector will light up.

Note:

 The conductors in electrical cord sets are often twisted. For best 

results, rub the probe tip along a length of the cord to assure placing 
the tip in close proximity to the live conductor. The detector is designed 
with high sensitivity. Static electricity or other sources of energy may 
randomly trip the sensor.

Auto Power Off

To preserve battery life, the meter is programmed to turn off after approx. 
30 minutes of inactivity.

Data Hold

1.  While taking a measurement, press the 

HOLD

 button to freeze the 

current reading on the display.

2.  While in this mode a "HOLD" symbol will appear on the LCD.
3.  Press the 

HOLD

 button again to resume normal operation.

Relative Mode

1.  Press the 

REL

 button to enter relative mode which will zero the 

reading and create a reference point.

2.  REL will appear on the LCD display. Future readings will display a 

value that is the difference between the actual reading and the stored 
relative reading.

Note:

 While in Relative mode, auto ranging is disabled and measurements 

are limited to the range that is active when the 

REL

 button was pressed.

3.  Press the 

REL

 button to exit relative mode and resume 

normal operation.

Note:

 Relative mode does not function in Frequency or Duty Cycle mode. 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 800837001276

Page 1: ...AC Clamp Meter Instruction Manual R5020 www com information itm com 1 800 561 8187...

Page 2: ...Resistance Measurements 10 Diode and Continuity Measurements 10 Capacitance Measurements 11 Frequency or Duty Cycle measurements 11 Type K Temperature Measurements 11 Non Contact AC Voltage Measureme...

Page 3: ...d under the manufacturer s warranty Servicing should only be provided by an authorized service center Do not exceed the maximum allowable input range of any function Do not apply voltage to the meter...

Page 4: ...ssed electrical contacts Features Measures AC current AC DC voltage resistance capacitance frequency duty cycle and temperature 4000 count LCD display with low battery and overrange indicators Built i...

Page 5: ...V DC 0 1mV 0 001 0 01 0 1 1V Resistance Range 400 4 40 400k 4 40M Accuracy 1 5 rdg 2 dgt 0 1 0 001 0 01 0 1k 0 001 0 01M Capacitance Range 40 400nF 4 40 100 F Accuracy 3 rdg 5 dgt Resolution 0 01 0 1n...

Page 6: ...on Contact Voltage Detector Yes Autoshut off Yes after 15 minutes Power Supply 2 x AAA Batteries Low Battery Indicator Yes Jaw Opening 1 2 30mm up to 350 MCM Overvoltage Category CAT III 600V Product...

Page 7: ...t AC Voltage Indicator Light 3 Clamp Trigger 4 MODE Selection Button 5 Frequency Duty Cycle Selection Button 6 LCD Display 7 COM Input Jack 8 Battery Cover 9 Data Hold Button 10 Rotary Switch 11 Relat...

Page 8: ...gative Reading Indicator 3 4000 Count Main Display 4 Temperature Units 5 Low Battery Indicator 6 Units of Measurement 7 Relative Mode Indicator 8 Data Hold Indicator 9 Audible Continuity Indicator 10...

Page 9: ...nge first then move to the lower range if necessary 2 Press the trigger to the open jaw and fully enclose one conductor only as shown 3 The LCD will display the reading AC DC Voltage Measurements 1 Se...

Page 10: ...nd Continuity Measurements 1 Set the rotary function switch to the position 2 Connect the test leads to the meter see Connecting the Test Leads section for details 3 Press the MODE button until the Di...

Page 11: ...n for details 3 Select Hz or duty with the Hz button 4 Touch the test probe tips to the circuit under test as shown 5 Note the frequency or duty cycle value on the LCD display Type K Temperature Measu...

Page 12: ...prox 30 minutes of inactivity Data Hold 1 While taking a measurement press the HOLD button to freeze the current reading on the display 2 While in this mode a HOLD symbol will appear on the LCD 3 Pres...

Page 13: ...es and Replacement Parts R2920 Surface Thermocouple Probe R2930 Right Angle Thermocouple Probe R2940 Air Gas Thermocouple Probe R2950 Immersion Thermocouple Probe R2960 Needle Tip Thermocouple Probe R...

Page 14: ...hat proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instrum...

Page 15: ...info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights...

Page 16: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www com information itm com 1 800 561 8187...

Reviews: