11
Capacitance Measurements
1. To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors before
taking any capacitance measurements. Remove the
batteries and unplug the line cords.
2. Set the rotary function switch to the CAP position.
3. Connect the test leads to the meter (see
Connecting
the Test Leads
section for details).
4. Touch the test leads to the capacitor under test as shown.
5. Note the capacitance value on the LCD display.
Frequency or % Duty Cycle measurements
1. Set the rotary function switch to the V position.
2. Connect the test leads to the meter (see
Connecting
the Test Leads
section for details).
3. Select Hz or % duty with the
Hz/%
button.
4. Touch the test probe tips to the circuit under test
as shown.
5. Note the frequency or % duty cycle value on the
LCD display.
Type K Temperature Measurements
Note:
To avoid electric shock, disconnect both test probes from any
source of voltage before making a temperature measurement.
1. Set the rotary function switch to °C or °F.
2. Plug the optional Type K Thermocouple Probe into the thermocouple
input jack.
3. Touch the Temperature Probe head to the area to be measured.
4. When the reading is stable (up to 30 seconds), note the
measured value.
Note:
In case of an open input or a temperature overrange, the meter
will display "OL". To avoid electric shock, be sure the thermocouple has
been removed before changing to another function.
continued...