Redx RX Series User Manual Download Page 3

 

 

Rev 20220606 

RX2505AC 

Page 

3

  of 

35

 

 

 

 

 

All

 

Rights

 

Reserved

 

No

 

part

 

of

 

this

 

document

 

can

 

be

 

reproduced

 

in

 

any

 

form

 

or

 

by

 

any

 

means

 

without

 

the

 

prior

 

written

 

permission

 

of

 

Redx.

 

 

Trademarks

 

 

 

 

and

 

other

 

Redx

 

trademarks

 

used

 

in

 

this

 

manual

 

are

 

owned

 

by

 

Redx.

 

All

 

other

 

trademarks

 

or

 

registered

 

trademarks

 

mentioned

 

in

 

this

 

document

 

are

 

owned

 

by

 

their

 

respective

 

owners.

 

 

Software

 

Licenses

 

It

 

is

 

prohibited

 

to

 

use

 

data

 

confirmed

 

in

 

firmware

 

or

 

software

 

developed

 

by

 

Redx,

 

in

 

part

 

or

 

in

 

full,

 

for

 

commercial

 

purposes

 

by

 

any

 

means.

 

It

 

is

 

prohibited

 

to

 

perform

 

reverse

 

engineering,

 

cracking,

 

or

 

any

 

other

 

operations

 

that

 

compromise

 

the

 

original

 

program

 

design

 

of

 

the

 

software

 

developed

 

by

 

Redx.

 

 

 

 

 

 

 

Contact

 

Us

 

 

Redx

 

Technology

 

Australia

 

Pty

 

Ltd

 

Address:

 

U2

 

/21

 

Millennium

 

Circuit,

 

Helensvale,

 

Australia

 

4212

 

Tel:

 

+61

 

7

 

5672 9983

 

Email:

 

[email protected]

 

Website:

 

www.redxenergy.com.au 

ABN: 76614340546

Summary of Contents for RX Series

Page 1: ...Rev 20220606 RX2505AC Page 1 of 35 User Manual RX SERIES ALL IN ONE RX 2505AC ...

Page 2: ...Rev 20220606 RX2505AC Page 2 of 35 ...

Page 3: ...heir respective owners Software Licenses It is prohibited to use data confirmed in firmware or software developed by Redx in part or in full for commercial purposes by any means It is prohibited to perform reverse engineering cracking or any other operations that compromise the original program design of the software developed by Redx Contact Us Redx Technology Australia Pty Ltd Address U2 21 Mill...

Page 4: ...a safe place Redx will not notify the user of any changes to this manual This manual applies to the RX 2505AC all in one energy storage integrated system The system must be installed by a qualified licensed technician The battery chemistry in the all in one energy storage system is lithium iron phosphate We strongly recommend that installers read this manual carefully The manual includes the guida...

Page 5: ...s 11 2 4 Name Plate Labelling 12 2 4 1 Product benefits 12 2 5 Scope of Delivery 13 2 6 Storage 13 3 Installation 13 3 1 Installation preparation 13 3 2 Installation Tools 15 4 Installation guide 16 4 1 System wiring diagram 16 4 2 Installation procedure 17 4 3 Earth Connection 17 5 Cable Connection 18 5 1 Connect cables to the AC grid side and off grid side 18 5 2 CT METER Connection 22 5 3 Exter...

Page 6: ... Standby Status 26 6 3 6 Protection Mode 26 6 3 7 Shutdown Status 26 6 4 Communication 27 7 RX 2505AC System turn on and turn off 27 7 1 Turn on RX 2505AC system 27 7 2 Turn off RX 2505AC system 27 8 Troubleshooting Maintenance 27 8 1 Troubleshooting 27 8 2 Maintenance 30 8 3 Routine Maintenance 31 9 Redx Technology App 31 10 Quality Assurance 31 11 Appendix 32 11 1 Product Specification 32 11 2 O...

Page 7: ...Redx is not responsible for any failure or loss arising out of improper operation d All wiring installation commissioning and other work should be done by a professional licensed technician e Ensure that the storage unit is not installed or used in the following locations Poorly ventilated room Places with inflammable gases or corrosive materials and large amounts of dust High or low Environment t...

Page 8: ...ors are discharged Danger Do not connect the grid cable to the EPS output otherwise it may cause Serious damage to the system and load Warning Installation must be in full compliance with national and local laws and regulations Warning Ensure that the system is positioned correctly and is not allowed to roll sideways nor is upside down Warning Do not change the internal circuit of the machine with...

Page 9: ...gy to the grid when needed It can also provide backup power during a power outage Figure 2 1 shows the application of the RX 2505AC all in one energy storage system RX 2505AC contains the inverter and battery storage modules It is important to keep the installation environment well ventilated and take necessary measures to control the ambient temperature to avoid the risk of explosion caused by ex...

Page 10: ...Main power Switch 2 Battery air circuit breaker 3 DRM0 RJ45 Terminal 4 RS485 USB 5 CT METER Terminal 6 EPS Terminal 7 AC Terminal 8 Battery status indicator 9 Run Indicator light 10 VPP Indicator light 11 Grid Indicator light 12 Battery Indicator light 13 Mounting bracket Table 2 1 Battery components details Table 2 2 Battery systems dimensions details ...

Page 11: ...Rev 20220606 RX2505AC Page 11 of 35 2 3 LED Indicator Panel and Switches Table 2 3 Battery interface details ...

Page 12: ... 2 4 1 Product benefits a Backup power supply peak shaving asset management b Integrated design save installation time and costs c Smart management different operating modes d Battery safety management system e Remote scheduling intelligent management f Multiple protection Table 2 4 Battery label specifications ...

Page 13: ...t installed immediately Store the unit in the original packaging box Storage temperature should be always between 0 C and 50 C Package dimensions 1025x755x330 mm weight 101 5kg Maximum stacking 5 pallets 3 Installation 3 1 Installation preparation a Indoor installation only IP32 b Vertically mount only c Install in a ventilated location There must be enough clearance to ensure that the module oper...

Page 14: ...ns in the unit regularly i Location shall be dry with adequate air flow pollution level 2 and without excessive dust j Wiring terminals require protective covers k Installation is prohibited in any of the following environments high temperature rain corrosion slope fire The minimum clearance on the sides must be maintained at least 300mm a Installation location of the system should be easy for ope...

Page 15: ...Rev 20220606 RX2505AC Page 15 of 35 Table 3 1 Installation tools 3 2 Installation Tools Prepare the following tools before installation ...

Page 16: ...orage system The RX 2505AC can be connected to a maximum of two wired CTs please note that the CT cable length should not exceed 10m Red indicates a power cable blue indicates a signal cable green indicates wireless communication The details are as follows Number Name A RX 2505AC B AC switch C Switchboard D Load E Smartmeter CT F Grid G Optional 4G Module H Auxiliary WLAN FE Module I APP J Managem...

Page 17: ... the m6x60 expansion screws into the previously drilled holes 4 Secure the fixing bracket to the wall using a socket wrench and tighten the expansion bolts 5 Align the unit with the fixing bracket on the wall and lift the unit on to the bracket by lowering it into the holes 6 Prepare the unit for installation of cabling 4 3 Earth Connection A secondary protection grounding terminal can be found on...

Page 18: ... table below is a recommendation for cable selection Engineers should refer to local standards to select cables Cable length is generally 2 to 10 meters long cable will lead to voltage drop from the rated value consequently requiring an increase of the cross sectional area Recommended specifications of AC circuit breaker The following table lists the recommended specifications of AC cables Model A...

Page 19: ... the grid before connecting the system to the grid 2 Grid voltage and grid frequency should be within the allowable range of inverter operation Steps 1 First prepare the required connecting wires according to the following It is recommended that the live wire be red the ground wire be black and the safety earth wire be yellow and green 2 Remove the cover of the terminal 3 Note the wiring terminals...

Page 20: ...l connects to PE in the switchboard Example countries that have this regulation Australia New Zealand Please follow local wiring regulations Note The battery inverter does not have an internal RCD as it is isolated If an external RCD breaker is mandatory in the country of installation it must be a type A RCD with the rating residual current not more than 30mA 1 2 3 4 5 6 Nuts GRID 3 core cable EPS...

Page 21: ...ckup power supply functions refer to Figure 5 6 to connect cables 3 The grid terminal and EPS terminal cannot be directly connected together otherwise the system will be damaged 4 The EPS terminal cannot be connected to the grid otherwise the system will be damaged 5 The battery needs to be activated by the grid when the system starts for the first time Figure 5 8 240V connection diagram On grid o...

Page 22: ...s shown in Figure 5 10 4 Connect the corresponding cable according to the label PV GRID on the CT METER Label GRID is for grid connection Label PV is for PV Connection See figure 5 7 and find CT Note RX 2505AC can have two CTs connected to it The CT can also be replaced with smart meter according to customer requirements Users can choose to use either CT or a smart meter CT cable length 5m specifi...

Page 23: ...devices 1 Unscrew the rubber nut on the water proof cover of the system RS485 2 The detail of the USB RS 485 as shown in Figure 5 12 Note The RX 2505AC has a Wi Fi module inside If customers use another Wi Fi module or other communication module they need use the default USB RS 485 port 5 4 Connection of DRM0 terminal Australia only When RX 2505AC is installed in some states in Australia the DRM t...

Page 24: ...cables are correctly connected properly distributed and well protected and no mechanical damage is present 3 The selection of AC circuit breakers is correct 4 The wiring terminals are securely installed and the vacant terminals are sealed 5 All safety signs and warning labels on the system are firmly and clearly visible 1 2 3 4 5 6 7 8 DRM0_1 DRM0_2 N A N A N A N A N A N A Figure 5 13 DRM cable as...

Page 25: ...main modes Local VPP or Timed mode The default is VPP mode most units should be configured as Local mode The Local mode includes on grid and off grid functions By default the Anti backflow function is enabled A On grid functionality 1 Anti backflow function enabled When anti backflow is enabled the unit will not send power back to the grid In VPP mode RX 2505AC works as per the commands sent from ...

Page 26: ... to normal working mode otherwise the system goes into the fault state 6 3 5 Standby Status When the system does not fault but certain operating conditions are not met the system will go into standby mode 6 3 6 Protection Mode Connecting an over size load to the EPS terminal will trip the unit and trigger protection mode The unit will try to restart 3 times if the load is still present the unit wi...

Page 27: ...rn on and turn off 7 1 Turn on RX 2505AC system You can perform the following steps to start the RX 2505AC 1 Connect to the grid 2 Turn on the battery circuit breaker 3 Turn on the power button 4 When the LED display is normal the system starts normally 7 2 Turn off RX 2505AC system 1 Turn the unit off from the power button 2 Turn off the battery circuit breaker 3 Turn off the AC circuit breaker 4...

Page 28: ...under voltage The input is suddenly disconnected 1 When the fault is recovered the inverter will automatically return to normal working state 2 If the external environment does not change and the alarm remains after the system is restarted contact installation partner DC Bus over voltage The rapid change of power grid voltage may cause high energy input to the inverter Internal dc dc converter or ...

Page 29: ...y 1 Wait for the inverter to recover automatically 2 If the alarm is repeated contact installation partner Bus soft start failed Bus voltage setup timeout 1 Wait for the inverter to recover automatically 2 If the alarm is repeated contact installation partner The inverter soft start failed Inverter output setup timeout Inverter phase lock failure Inverter phase lock fault 1 Wait for the inverter t...

Page 30: ...2400 2 Check whether the communication cable is loose 3 Contact installation partner DSP communication error Grid Short Circuit The AC input is a short circuit 1 Check whether the AC input cable of the inverter is short circuited 2 If the error message persists contact installation partner Load short circuit Output is a short circuit 1 Remove load 2 Restart system Danger RX 2505AC has lithium batt...

Page 31: ...joy the following after sales warranty service 1 A 5 year warranty commences from the date of shipment during the warranty period the company provides free repair or replacement of product 2 Any paid service extended warranty is available from the date of shipment from manufacturer 3 Disclaimer Product faults caused by the following reasons are not within the scope of the manufacturer s 5 years wa...

Page 32: ...ustomer fails to pay off the products according to the Purchase and Sales Contract signed by both parties c The user intentionally conceals the improper use of the product during installation wiring operation maintenance or other processes to the after sales service provider of the manufacturer Redx reserves the right to change the contents of this specification and product performance without inf...

Page 33: ...Rating IP32 Operating temperature range charging discharging 0 50 20 50 Environment temperature range 20 45 Relative humidity 10 100 Cooling Natural cooling Acoustic Noise 40dB Max Altitude 2000m Inverter topology Isolated Overvoltage category AC III DC II Active anti islanding method Reactive disturbance The decisive voltage class AC DVC C Other ports DVC A DC DC topology High frequency transform...

Page 34: ...KA Rated short circuit making capacity Icm 10KA Rated breaking capacity 10KA Islanding protection YES Anti backflow YES DC reverse connection protection YES AC output short circuit protection YES Over frequency and under frequency protection YES Overvoltage or undervoltage protection YES DC fuse battery side YES Overcurrent protection including Battery overcurrent YES Over temperature protection Y...

Page 35: ...mber 2 System model 3 Fault code Name 4 Briefly describe the fault symptom For more information please scan QR code above or log in directly www redxenergy com au Download the Redx App with the above QR Code Address Unit 2 21 Millennium Circuit Helensvale QLD Australia 4212 Website www redxenergy com au Email info redxenergy com au Phone 61 7 56729983 Specifications are subject to change without a...