![Redsail RS3040A User Manual Download Page 10](http://html1.mh-extra.com/html/redsail/rs3040a/rs3040a_user-manual_1430145010.webp)
Redsail Laser
IV Basic operation procedure
1. Starting up
1) Start the water pump; let the water in laser tube circulate for 3 minutes.
2) Turn on the power of machine.
3) Turn on the power of blower fan.
4) Turn on the laser power, and press “test” button to see if there is ray.
5) Use the arrow key to move the laser head, make sure that it can be moved.
6) Adjust the work plate, and fix up the focus length.
7) Operate the Easycut 2.0 in the computer to start work.
2. Shut down
Turn off the machine, blower fan, water pump.
V Cautions and maintenance
1. Safety cautions
1) It is forbidden to start the machine without grounding. The ground wire of
machine must be connected with the earth. It can not be connected on facilities such as
doors, windows, water pipes, and so on. The wire should be pulled to the outdoor ground.
2) Check the submersible water pump to see if it can let the water out each time
after starting the machine. It is forbidden to start the machine up when water can not come
out form the pump.
3) Operators can not leave the machine when it is working so as to avoid
unnecessary loss.
4) Water container should be a bit larger to make sure that there is at least 10
Liter water in circulation. The water temperature should be under 25
o
C. If the temperature
is too high, the water should be changed. It is better to use pure water so that here isn’t
any contaminant. Circulating water should be changed regularly (every day).
5) Because there is laser and high volt in the machine, non-professional workers
should not disassemble the machine without authorization.
6) Reflect mirror and focus lens should be wiped with special camera lens paper
or medical-use cotton wetted by mixture of alcohol and ether. Cleaning of mirrors and lens
should be done once a week. It is required that the grounding of all parts of the machine
and user's computer should be safe to avoid damage of machine and injuries caused by
Redsail Tech Co., Ltd