Fixing 

(see Diagram 1) 

 

The wall bracket should be securely fixed in position. 
The heater is then hung on the wall bracket. 

Further security can be obtained by marking the position of the extra fixing holes as 
shown and applying appropriate wall fixings to these positions. 
 
 
 
 
 

 
 
 
 

 
 

 
 
 
 

 
 
 
 
 

 

When the unit is used above the sink with the cold inlet tap and spout supplied, it is 
recommended that these extra fixing positions be used.  
The bottom of the heater should be approximately 350mm above the top of the sink. 

 

The outlet should be at least 13mm above the maximum possible water 
level for any unit that is to be filled from the heater. 

 

Electrical Connection 

 

The installation must be in accordance with the current BS7671  - IEE Wiring Regulations 
and “Part P” of the Building Regulations. 

 

WARNING: THE UNIT MUST BE FILLED WITH WATER 

 BEFORE POWER IS SWITCHED ON. 

 

1.

 

The heater is suitable for 240/230V single phase A.C supply. 

 

2.

 

The live (brown) and neutral (blue) wires must be connected                                                     
to the designated positions in the terminal block and the                                                               
earth     (green/yellow) to the earth position. 

 

3.

 

WARNING: THIS UNIT MUST BE EARTHED 

 

4.

 

The mains cable should be prepared as shown (see Diagram 2) 

 

5.

 

A means for disconnection in all poles must be incorporated in           

    the fixed wiring in accordance with the wiring rules.   

 

6.

 

The cable should be heat resisting 3-core flexible PVC of 1.25mm² minimum. 

 

 

Installation Engineer Note: 

The most likely reason for no heated water is an open circuit thermal fuse. 

See label on front insulation for details. 
This can be caused at initial commissioning if the heating element is energized with no 
water in the tank. 
Alternatively, it may be due to a back siphonage in the cold water supply caused by a 

break or disconnection.   
If you feel that your installation may suffer from a water failure, we recommend the 

fitting of a non-return water check valve. 

 
After Sales Service 

 

We offer a technical advisory service on the telephone to contractors and other 
customers with problems in the field. 

 

Ring: 0844 372 7766 

Fax:  0844 372 7767 

 

Remember to quote the exact type of unit, as written on the front of this leaflet.                                           
It may also be of use to have a note of the model and serial number as stated on the 
underside of the unit. 

 

Common Spare Parts and Recommended Accessories 

 

 The fitting of Spare Parts must be supervised by a suitably qualified  person. 

 

Common Spare Parts  

 

 

Recommended Accessories 

 

Thermal Fuse  

Cat No. 94-780456 

Swivel Arm (450mm)  Cat No. 84-780404 

7-Day Timer 

Cat No. 94-780457 

Swivel Arm (600mm)  Cat No. 84-780405 

Front Cover Assy Cat No. 94-780458 

Monoblock Mixer Tap  Cat No. 84-780408 

 

Common Spare Parts and Recommended Accessories can be supplied from 

Redring Sales Hotline (RING) 0844 372 7766 or (FAX) 0844 372 7767 

 

Circuit Diagram 

Summary of Contents for WS7-EcoT

Page 1: ...n should only be carried out by a suitably qualified person The Redring WS7 EcoT heater is an open outlet thermal storage water heater for use with Redring recommended fittings for one outlet only It operates on the displacement principle i e when cold water is admitted into the bottom of the tank hot water flows out through the outlet Installation We recommend that this unit should be installed i...

Page 2: ...the wiring rules 6 The cable should be heat resisting 3 core flexible PVC of 1 25mm minimum 7 Installation Engineer Note The most likely reason for no heated water is an open circuit thermal fuse See label on front insulation for details This can be caused at initial commissioning if the heating element is energized with no water in the tank Alternatively it may be due to a back siphonage in the c...

Page 3: ...to cool or that any hot water is run through the heater before commencing this operation The heater must be disconnected from the electrical supply before commencing this operation Take care to protect the mechanical programmer from any water If the unit fails to heat water 1 Check that the switching time on the mechanical programmer is set to be ON 2 Check that the mechanical programmer is not in...

Page 4: ... hours and 20 minutes A major benefit of the Redring WS7 EcoT heater is the energy saving possibilities of controllability and the facility in a commercial installation to set a programme to cover a weekly usage pattern including weekends However the thick insulation contained in the Redring WS7 EcoT heater also ensures economic running costs if the heater is left on at all times Setting up the we...

Reviews: