b)

The heater must not be mounted in the
direct spray from the handset.

c) The handset must not be able to come into

contact with the used water in the cubicle,
bath or basin. If it can, even after the hose
has been retained by the hose retainer (see
diagram 12), then a vacuum breaker must be
fitted. It should be noted that these devices
are liable to minor leakage so they must be
positioned so that any drips are not
detrimental.

4. Fix the riser rail with screws provided. 

The fixing holes at the base of the brackets
will be revealed by removing the plastic fronts.
Assemble as shown in diagram 12.

5. Decide the position of the electrical cable to

the unit. If top or bottom entry is chosen,
carefully cut away the relevant walls of the
backplate as shown in diagram 6.

6. Decide the position of the cold water pipe into

the unit. If top or bottom entry is chosen,
carefully cut away the relevant walls of the
backplate as shown in diagram 6. If bottom
entry is chosen refer to note 4 in the plumbing
section.

7. If you have not yet done so, remove the front

cover (complete with knobs) by undoing the
retaining screws at the top and bottom of the
unit. Your shower is provided with three fixing
positions in the backplate (see diagram 6).
The top fixing hole is a key-hole slot and
should be marked and drilled first. Tighten top
screw with head protruding about 10mm from
wall and hook the backplate over the screw
head. This allows for correct and accurate
alignment of your shower before marking and
fixing the bottom positions. You may not wish
to tighten up the screws at this stage as the
holes are elongated to allow for adjustment
after other connections have taken place.

B) Plumbing

WARNING : - UNDER NO CIRCUMSTANCES
SHOULD THIS UNIT BE CONNECTED TO
THE MAINS COLD WATER SUPPLY.

The heater should be connected to a cold water
supply gravity fed from a static cold water cistern
with a minimum capacity of 114 litres (25 galls).
There must be a minimum head of water of 8 cm
(3") and a maximum head of 10 metres (33ft).

It is strongly advised to install the shower unit
using an independent supply from the cold water
storage cistern. The shower would then be totally
unaffected by other draw off points elsewhere in
the system and thus the pressure and
temperature will remain more stable. Therefore
the cold water supply should be taken directly
from the cold water cistern.

Under no circumstances should any of the
pipework supplying the shower unit rise
above the level of the bottom of the cold
water cistern.

Before connecting the pipework to the shower
ensure that the pipework is flushed out.

1. It is recommended that a water council listed

isolating valve is fitted between the cold water
storage cistern and the shower unit. This will
allow the shower unit to be serviced without
turning off the cold water at the water stop
valve and draining the cold water cistern.

2. 15mm copper pipe should be used. 

Ensure

all burrs have been removed from the
pipes before inserting into the push fit
inlet ports.

Diagram 8 illustrates the correct

procedure for inserting and removing the
pipes from the inlet ports.

Take care to line up the inlet pipe correctly
with the inlet port to avoid straining the
internal 'O' ring seal.

DO NOT use solder fittings within 300mm
of plastic fittings.

3. To maintain the optimum performance, the

pipe runs should be kept as short as
possible, using sweeping bends rather than
right angles or restrictive fittings.

4. If bottom entry has been chosen, the inlet

port must be rotated through 180

0  

into the

required position. To do this unscrew the side
section from the shower unit (see diagram 6).
Rotate inlet connection ensuring that a snug
fit into the cradle is achieved, replace side
section retaining screw and remove the side
section and tighten screw.

5. With an isolating valve connecting, 

flush the

pipework through to remove particles
etc. 

before making the final connection to the

shower. A blockage in the waterways
(particularly the spray rings and filter) will
prevent the shower unit working properly.

7

Summary of Contents for EXPRESSIONS 570

Page 1: ...Installation instructions User guide IMPORTANT This booklet should be given to the customer after installation and demonstration WARNING Under no circumstances should this unit be connected to the mains cold water supply 570 ...

Page 2: ...ER ON IF YOU SUSPECT IT OF BEING FROZEN WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT HOW TO USE YOUR REDRING SHOWER 1 Ensure the electricity and water supplies are turned on to the unit 2 Your shower has 2 power settings selected by turning knob A The most popular setting is HIGH indicated by high power There is also a LOW power option indicated by low power See note 7 For this example turn knob A to...

Page 3: ... DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT HOW YOUR REDRING SHOWER WORKS Your Redring shower is designed for convenience economy and safety of use 1 Water is heated instantaneously as it flows over the heating elements in the copper cylinder assembly 2 The required water temperature is achieved by adjusting the rate of water flow Diagra...

Page 4: ... outer spray pattern only This will ensure correct operation of the shower with a slightly lower water flow rate NOTE After use it is normal for some water to drip from the shower head for a few moments Cleaning It is recommended that the shower unit and accessories are cleaned using a soft cloth DO NOT use powerful abrasive or solvent cleaning fluids It is advisable to switch off the shower at th...

Page 5: ... but no water is delivered Water starvation Stop pump immediately by turning knob B fully clockwise to the Stop position Check the cold water cistern is full Ensure water supply pipe is not blocked or air locked Re prime shower unit see commissioning with power to shower switched off c Pump operates but no water is delivered Thermal trip inside motor has operated Wait for motor to cool down approx...

Page 6: ...ure relief disc e Water leaks from burst pressure relied valve Diagram 6 A Fixing the shower to the wall The Redring Expressions 570 Pumped Electric Shower is fitted with a motor and some mechanical noise can be expected when in use The type of wall structure will affect the noise levels Solid walls will provide quieter operation than panel or stud partition walls 1 Place the riser rail at the hei...

Page 7: ...25 galls There must be a minimum head of water of 8 cm 3 and a maximum head of 10 metres 33ft It is strongly advised to install the shower unit using an independent supply from the cold water storage cistern The shower would then be totally unaffected by other draw off points elsewhere in the system and thus the pressure and temperature will remain more stable Therefore the cold water supply shoul...

Page 8: ...1 clipped direct is used The maximum cable run for all models above will depend upon site conditions REMEMBER TO UPRATE THE CABLE IF IT RUNS IN THERMAL INSULATION IN A LOFT 3 In order to provide a means of isolation the heater MUST BE permanently connected to the electricity supply through a double pole linked switch with a contact gap of 3mm mounted in a convenient position We recommend ceiling s...

Page 9: ...f Turn control knob B fully anti clockwise Water should start to flow with motor switched off allowing all the air to be purged out of the shower unit It may be necessary to lower the hose below the level of the shower unit whilst priming Stop water flow by turning knob B fully clockwise Attach handset switch on electrical supply and then operate the shower as on page 2 and check a That the water ...

Page 10: ...10 ASSEMBLY OF RISER RAIL HANDSET AND SOAP DISH Removable insert in soap dish for ease of cleaning Locating Key Additional knock out fixing slot if required Diagram 12 ...

Page 11: ......

Page 12: ...mencement of hire purchase we will replace the defective parts FREE OF CHARGE on condition that The appliance has been correctly installed and used only on the supply circuit or voltage stamped on the rating plate The appliance has been used in accordance with these instructions and has not been tampered with or otherwise subjected to misuse neglect or accident The appliance has not been taken apa...

Reviews: