background image

temperature climbs above a set limit and the

'overheat'

light will come on. This cut-out

which gives an audible click, may also
operate due to residual heat when the shower
is switched off. It will reset itself if cold water
is run through the shower for 10 to 20
seconds and the 

'overheat'

light will go out.

8. A pressure relief device is fitted to safeguard

against extreme abuse conditions.

9. There are three defined plate spray settings

adjustable by rotating the spray plate (see
diagram 4). If desired many combinations
between the 3 can be achieved.

HOW TO MAINTAIN YOUR
'REDRING' SHOWER

All water contains particles of lime which build up
in the showerhead and unit reducing the
performance. It is therefore important to clean the
showerhead by regularly dipping it in a suitable
de-scaling solution. The frequency of this will vary
from weekly to quarterly.

Check the srayplate is then free to rotate to give
the three setting. In some winter conditions,
when incoming water from the cold water storage
cistern is particularly cold it may be necessary to
select the inner or outer spray pattern only. This
will ensure correct operation of the shower with a
slightly lower water flow rate.

NOTE:

After use it is normal for some water to drip from
the shower head for a few moments.

Cleaning

It is recommended that the shower unit and
accessories are cleaned using a soft cloth.

DO NOT

use powerful abrasive or solvent

cleaning fluids. It is advisable to switch off the
shower at the isolating switch to avoid the
shower accidently switching on.

WHAT TO DO IF THINGS GO
WRONG

Self Help

If the performance of the shower does deteriorate
in service make the following checks before
calling out the contractor. Any one of these
simple adjustments could restore the
performance.

Diagram 4

'CASCADE'
(inner/outer)

'SURF'
(outer spray
only)

'SPORT'
(inner spray
only)

Diagram 5

The spray head rotates
through approximately 140

o

IN ORDER TO MAINTAIN THE
PERFORMANCE OF YOUR
SHOWER YOU MUST CLEAN
THE SHOWERHEAD.

Increase water flow by
adjusting the temperature
control (knob B) anti-clockwise
to a lower number on the
temperature scale.
Clean the showerhead.
Switch power to 

'

low

power '

setting . 

Select outer or combination
spray pattern.
Increase pressure of water
supply e.g. fully open service
valve.
Check hose is not kinked
restricting the water flow.

a) Water too

HOT

4

a)

b)

c)

Summary of Contents for EXPRESSIONS 570

Page 1: ...Installation instructions User guide IMPORTANT This booklet should be given to the customer after installation and demonstration WARNING Under no circumstances should this unit be connected to the mains cold water supply 570 ...

Page 2: ...ER ON IF YOU SUSPECT IT OF BEING FROZEN WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT HOW TO USE YOUR REDRING SHOWER 1 Ensure the electricity and water supplies are turned on to the unit 2 Your shower has 2 power settings selected by turning knob A The most popular setting is HIGH indicated by high power There is also a LOW power option indicated by low power See note 7 For this example turn knob A to...

Page 3: ... DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT HOW YOUR REDRING SHOWER WORKS Your Redring shower is designed for convenience economy and safety of use 1 Water is heated instantaneously as it flows over the heating elements in the copper cylinder assembly 2 The required water temperature is achieved by adjusting the rate of water flow Diagra...

Page 4: ... outer spray pattern only This will ensure correct operation of the shower with a slightly lower water flow rate NOTE After use it is normal for some water to drip from the shower head for a few moments Cleaning It is recommended that the shower unit and accessories are cleaned using a soft cloth DO NOT use powerful abrasive or solvent cleaning fluids It is advisable to switch off the shower at th...

Page 5: ... but no water is delivered Water starvation Stop pump immediately by turning knob B fully clockwise to the Stop position Check the cold water cistern is full Ensure water supply pipe is not blocked or air locked Re prime shower unit see commissioning with power to shower switched off c Pump operates but no water is delivered Thermal trip inside motor has operated Wait for motor to cool down approx...

Page 6: ...ure relief disc e Water leaks from burst pressure relied valve Diagram 6 A Fixing the shower to the wall The Redring Expressions 570 Pumped Electric Shower is fitted with a motor and some mechanical noise can be expected when in use The type of wall structure will affect the noise levels Solid walls will provide quieter operation than panel or stud partition walls 1 Place the riser rail at the hei...

Page 7: ...25 galls There must be a minimum head of water of 8 cm 3 and a maximum head of 10 metres 33ft It is strongly advised to install the shower unit using an independent supply from the cold water storage cistern The shower would then be totally unaffected by other draw off points elsewhere in the system and thus the pressure and temperature will remain more stable Therefore the cold water supply shoul...

Page 8: ...1 clipped direct is used The maximum cable run for all models above will depend upon site conditions REMEMBER TO UPRATE THE CABLE IF IT RUNS IN THERMAL INSULATION IN A LOFT 3 In order to provide a means of isolation the heater MUST BE permanently connected to the electricity supply through a double pole linked switch with a contact gap of 3mm mounted in a convenient position We recommend ceiling s...

Page 9: ...f Turn control knob B fully anti clockwise Water should start to flow with motor switched off allowing all the air to be purged out of the shower unit It may be necessary to lower the hose below the level of the shower unit whilst priming Stop water flow by turning knob B fully clockwise Attach handset switch on electrical supply and then operate the shower as on page 2 and check a That the water ...

Page 10: ...10 ASSEMBLY OF RISER RAIL HANDSET AND SOAP DISH Removable insert in soap dish for ease of cleaning Locating Key Additional knock out fixing slot if required Diagram 12 ...

Page 11: ......

Page 12: ...mencement of hire purchase we will replace the defective parts FREE OF CHARGE on condition that The appliance has been correctly installed and used only on the supply circuit or voltage stamped on the rating plate The appliance has been used in accordance with these instructions and has not been tampered with or otherwise subjected to misuse neglect or accident The appliance has not been taken apa...

Reviews: