RDL-3000
FAMILY
USER MANUAL
70-00158-03-00
Proprietary Redline Communications © 2015
Page
82
of 254
April 17, 2015
4.
Depending on availability and RF conditions, forcing a rescan may result in the
subscriber registering with the same sector controller.
5.
Scan results are discarded immediately following a successful registration.
6.
Remote terminals may be unable to register with sector controller due to the
following configuration issues:
- Remote unit security SC MAC field does not match SC MAC address
- Remote unit security SC MAC field not set to '00:00:00:00:00:00' (any SC)
7.
Sector controllers may not accept a subscriber registration request due to the
following configuration issues:
- SC does not have a Normal Link definition matching the remote unit MAC address.
- SC does not contain an STID Template with the requested name.
- SC contains the named STID Template, but the password does not match.
- SC and remote unit wireless encryption settings are not identical.
- SC and remote unit Cyclic Prefix settings are not identical.
- SC and remote unit Channel Size settings are not identical.