5
SET UP
1.FILL / ADD VAPOR PRODUCING FLUID
a. Remove fluid fill plug with hex key.
b. Pour OEM-Approved Vapor Producing Fluid into fluid
fill port.
c. Fill fluid fill port until fluid level is near top of port.
d. Replace fluid fill plug.
2 fl. oz. (60 ml) maximum to refill when empty
2. CONNECT TO POWER
• Use the power selector switch on rear of machine to
select input power, AC or DC.
• If 12 Volt DC is preferred, connect the battery cables to
a fully charged 12 Volt battery. RED to positive, BLACK
to chassis ground.
• If AC power is preferred, connect a properly rated
power cord into the AC Power Port.
• Green Power Indicator lamp illuminates with proper
power hook up and power source selected.
!
Never connect HD PowerSmoke
™
to a battery charger or jumper box.
Never connect HD PowerSmoke
™
to vehicle with engine running.
3. CONNECT TO AIR SUPPLY
a. Connect compressed air supply to Air Inlet.
*Replace quick coupler fitting if necessary. 1/4 in. NPT male.
4. Adjust HD PowerSmoke
™
for testing
a. Turn Flow Control Valve off.
b. Set desired Test Pressure. (
PULL
to unlock,
TURN
to adjust pressure,
PUSH
to lock)
c. Attach Vapor Hose to installed adaptor of system being tested.
d. Depress the
Vapor Test Switch (#5)
button to begin 15-minute vapor test cycle.
e. Turn Flow Control Valve to release pressure / vapor.
f. Use halogen inspection light provided to inspect for leaks.
!
!