MegaPlus ES 1020
User’s Manual
Redlake MASD, Inc.
Page
2
91000134-001 Rev. A
PRECAUTIONS
WARNING!
LIFE SUPPORT APPLICATIONS POLICY
MegaPlus cameras are not authorized for and should not be used within life support systems without the
specific written consent of Redlake MASD, Inc.
NON-CRITICAL MEDICAL APPLICATIONS
MegaPlus cameras must be grounded to building earth ground while operating. This camera has passed
IEC 601 class B standards.
The voltage drop on the camera’s power return line must be less than 0.5 Volts DC. Use a heavier gauge
power cable to reduce the voltage drop below 0.5 Volts DC. For medical applications, any power supply
connected to the camera must meet IEC 601 specifications.
Absolute Maximum Ratings
Input Voltage: 10 to 16V DC
Storage Temperature: -55°C to +70°C.
Recommended Maximum Ratings
Input Voltage: 11 to 14V DC
Internal Operating Temperature: -0°C to +85°C.
Recommended Operating Conditions
Input Voltage: 12V DC ± 0.5V
Internal Operating Temperature: -0°C to +65°C.
ESD
The camera contains class I static sensitive parts. Appropriate precautions should be taken when
handling or connecting or disconnecting cables.
FCC DECLARATION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.