Appendix C Advanced Functions
Timing Generator Control Register 1
15
14
13
12
11
10
9
8
TRIGGER
POL
PARTIALSC
AN EN
FLIP BITS
SINGLE TAP
TRIGGER
ENABLE
TME
ENABLE
TDE
ENABLE
RESERVED
7
6
5
4
3
2
1
0
TEST
PATTERN
ENABLE
TG SOFT
RESET
8 Bit CL
output
TAP FLIP
VBIN
4/2
VBIN
ENABLE
HBIN
4/2
HBIN
ENBLE
•
TRIGGER POL(ARITY)
Set to 0 for negative trigger pulse
Set to 1 for positive trigger pulse
•
PARTIAL SCAN ENABLE: Single tap output mode for testing
Set to 1 to enable operation
•
FLIP BITS: Flips data bits from msb to lsb
Set to 0 to enable msb in bit 0
Set to 1 to enable lsb on bit 0
•
SINGLE TAP: Single/Dual tap readout selection
Set to 1 to enable single tap operation
Set to 0 to enable dual tap operation
•
TRIGGER ENABLE: Select Trigger mode of operation
Setting this bit to 1 will cause the TG to enter the external trigger mode
•
MANUAL EXPOSURE: Manual trigger mode selection
Set to 1 to enable single tap operation
Set to 0 to enable dual tap operation
•
TDE ENABLE: Trigger Double Exposure Enable
Set to 1 to enable TDE mode
Set to 0 to disable TDE mode
•
TEST PATTERN ENABLE:
Setting this bit to 1 will cause the TG to output a fixed gray pattern with grid overlay.
Set to 0 to disable the test pattern
•
TG SOFT RESET: Timing Generator State Machine Reset
Set to 1 to re-initialize TG state machine
Set to 0 to resume normal operation
•
8 Bit CL Output (SINGLE TAP ONLY)
Setting this bit re maps the camera link output to 8 bits per tap.
The 8 most significant bits of the ADC are used.
•
TAP FLIP
Setting this bit to 1 will cause the TG to flip taps.