![Redexim RINK DS 3800 Operating Instructions And Spare Parts Book Download Page 15](http://html.mh-extra.com/html/redexim/rink-ds-3800/rink-ds-3800_operating-instructions-and-spare-parts-book_1429072015.webp)
DS3800
- 15 -
External oil supply
#
Change hydraulic tank oil (as required)
- Unscrew filler plug (1A).
- Release suction hose (2A), drain oil and refit suction hose.
- Unscrew oil filter (4A) and replace with new oil filter.
-
Fill
Plantosyn 3268 ECO
oil up to middle of sight glass (3A) (~ 70l).
- Screw in the filler plug using a new gasket.
This is a closed hydraulic circuit. To prevent any contamination, the oil
filter (4A) must be replaced every 100 operating hours.
Change filter after every 100 operating hours
- Unscrew oil filter (4A) and replace with new oil filter.
Used oil poses a danger to the environment; please dispose in
an environmentally friendly manner.
Fig.9: External oil supply
3A
2A
2A
4A
1A