69
7.8.2
Mount gas spring
(N)
onto the left side
ladder lift
arm
(E)
with:
- factory hardware
- Gas shock should be mounted rod end down
Ensure Short Stud
(B)
is connected to ladder lift arm
(E)
Ensure Longer Stud
(C)
is connected to left ladder mount
plate
(AL)
7.8.3
Repeat for right side
Ensure Short Stud
(B)
is connected to ladder lift arm
(E)
Ensure Longer Stud
(C)
is connected to Plate Ladder
Mount Left
(AR)
Longer stud should be located at
the top of gas shock. They may
need to be switched
7.9.1
Install door proximity sensor mount bracket (
Z
)
on
to the top of the left ladder skin (
SL
) prior to installation of
skin onto combine, with:
- M8 x 20 flange bolt and flange nut (
Z1
) x2
Z
Z1
Y
E
Z1
AL
B
C
7.9
Door Proximity Sensor Bracket Installation
Parts List:
part included in CS975BS box
hardware located in CS859S
CS851B
Bracket Door Prox Sensor (
Z
)
Qty 1
RP953
Extension Harness (
C
)
Qty 1
7.9.2
Install proximity sensor into sensor mount bracket (
Z
)
- reinstalled/relocated from spreader linkage
- final adjustment will occur after straw door has been
installed
SL
7.9.3
Connect wire extension harness (
C
) to proximity
sensor (
D
) and to connector at original position of sensor
on spreader linkage
C
Z
D
C