background image

www.sureheat.com

200305-01C

22

CARE AND MAINTENANCE

 WARNING: Turn off heater and let cool before servicing.

 CAUTION: You must keep control areas, burner, and circulating 

air passageways of heater clean. Inspect these areas of heater before 

each use. Have heater inspected yearly by a qualified service techni-

cian. Heater may need more frequent cleaning due to excessive lint 

from carpeting, bedding material, pet hair, etc.

  WARNING:  Failure  to  keep  the  primary  air  opening(s)  of  the 

burner(s) clean may result in sooting and property damage.

MAIN BURNER

We recommend that you clean the unit ev-

ery 2,500 hours of operation or every three 

months. We also recommend that you keep 

the  burner  tube  and  pilot  assembly  clean 

and  free  of  dust  and  dirt.  To  clean  these 

parts we recommend using compressed air 

no greater than 30 PSl. Your local computer 

store, hardware store, or home center may 

carry compressed air in a can. You can use 

a vacuum cleaner in the blow position. If us-

ing  compressed  air  in  a  can,  please  follow 

the directions on the can. If you don’t follow 

Figure 28 - Pilot Inlet Air Hole

directions on the can, you could damage the 

pilot assembly.
1.  Shut off the unit, including the pilot. Allow 

the unit to cool for at least thirty minutes.

2.  Remove four screws securing front panel.
3.  Pull front panel forward.
4.  Inspect burner and pilot for dust and dirt.
5.  Blow air through the ports/slots and holes 

in the burner.

6.  Replace  front  panel  using  screws  re-

moved in step 2.

ODS/PILOT

Periodically inspect all burner flame holes with 

the heater running. All slotted burner flame 

holes should be open with yellow flame pres-

ent. All round burner flame holes should be 

open with a small blue flame present. Some 

burner flame holes may become blocked by 

debris or rust, with no flame present. If so, 

turn off the heater and let it cool, and remove 

blockage or replace burner. Blocked burner 

flame holes will create soot.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

Use a vacuum cleaner, pressurized air, or a 

small, soft bristled brush to clean.
A yellow tip on the pilot flame indicates dust 

and dirt in the pilot assembly. There is a small 

pilot  air  inlet  hole  about  2"  from  where  the 

pilot flame comes out of the pilot assembly 

(see Figure 28). With the unit off, lightly blow 

air through the air inlet hole. You may blow 

through a drinking straw if compressed air is 

not available.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to 

clean.

Exterior

•  Use a soft cloth dampened with a mild soap 

and water mixture.

•  Wipe the cabinet to remove dust.

Pilot Air 

Inlet Hole

Natural Gas 

Burner

Propane/LP 

Gas Burner

Thermocouple

Pilot Air Inlet Hole

Ignitor 

Electrode

Summary of Contents for BWH30NLTE-2

Page 1: ...ot touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Page 2: ...s manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For a...

Page 3: ...er serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at hi...

Page 4: ...off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately ca...

Page 5: ...n either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali fied installer follow...

Page 6: ...UCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per hou...

Page 7: ...eathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from...

Page 8: ...to adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From O...

Page 9: ...kerosene lamps etc in the air exist maycausewallstodiscolor Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial...

Page 10: ...ounting bracket is located on back panel of heater It has been taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on...

Page 11: ...ne up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Marking Screw...

Page 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 10 Mounting Heater Onto Mounti...

Page 13: ...void gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator...

Page 14: ...ile pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Insta...

Page 15: ...the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulator with wren...

Page 16: ...lator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment...

Page 17: ...l leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 8 Replace front panel 1 Open equi...

Page 18: ...n above 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If yo...

Page 19: ...ousing construction TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise to the OFF position Shutting Off Burner Only pilot stays lit Turn control knob clockwise to the PILOT p...

Page 20: ...Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing colorcodingandsecur ing loca...

Page 21: ...to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING I...

Page 22: ...es 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel us...

Page 23: ...life and require no further lubrication However periodic cleaning vacuuming of the appliance around the air intake and exhaust as well as the fan heater is recommended For heavy or continuous use per...

Page 24: ...valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page...

Page 25: ...t 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold pressure is t...

Page 26: ...products Heater produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page23 2 Gas leak See Warning State ment at the top of page 23 3 Low fuel sup...

Page 27: ...ontact your local gas supplier REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Call Customer...

Page 28: ...www sureheat com 200305 01C 28 PARTS MODEL BWH30NLTE 2 2 11 3 9 8 7 1 12 10 5 6 14 13 15 12 16 4 17...

Page 29: ...161133 01 Piezo Ignitor 1 4 161130 01 Thermostat Valve Assy 1 5 Burner Assembly 1 6 161139 01 ODS Pilot 1 7 Dual Fuel Regulator 1 8 161200 01 Inlet Cover Plug 1 9 160960 01 Cap with Seal 1 10 Bezel T...

Page 30: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 31: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 32: ...ge resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...