11
OL28X
TM
TROUBLE SHOOTING
•
Keep level and accessories stored in protective case.
•
Make sure level is stored dry, dry out before storage to prevent damage.
•
The OL28X
TM
is a precision instrument and should not be subjected to excessive
knocks, drops or vibrations.
•
Self check calibration from time to time. See page 10
•
For service contact Redback Lasers.
www.redbacklasers.com.au
Q.
I cannot see a cross hair through eyepiece!
A.
The cross hair needs focusing for your eye sight by rotating the
adjustment ring on the eyepiece itself.
Q.
The Bubble Vial does not stay exactly central when I
rotate the level on its base.
A.
This is nothing to worry about the bubble vial is just a rough
levelling device to get the self levelling compensator into
working range, as long as the bubble is any where within the
circle then the compensator can accuratly self level. Getting the
bubble exactly central will NOT increase accuracy.