4.2.3 Connect oil hose
After the column is installed on the electrical oil pump, align the oil pipe to the oil outlet hold of electrical
oil pump and tighten the screw cap, as the following figure
4.2.4 Accessories list
Outer hexagonal screw M18x45:
18pcs
Flat gasket M18:
18pcs
Screw M10X20:
6pcs
Spring washer:
18pcs
Outer hexagonal screw M8X16:
4pcs
Flat gasket M8:
4pcs
Round head screw M8X12:
2pcs
Round head screw M6X10:
2pcs
Chain cover:
1set
Shaft Φ38x125:
2pcs
- Torque for fastening:
*screws: 8kg
*hydraulic hose: 6kg.
5. Operation rules
5.1 Operation rules for mechanical moving system
The movable single post lifter is provided with separate traveling mechanism. Shake the tiller of the hydraulic
movable set, rear wheel forwards and backwards to make the column off the ground, then you can push or
pull the lifter. On arriving the working site, press the release handle to retract the wheel, then the column lands
on the ground steadily.
The lifter must only be pushed into the vehicle if in line with it. Insert the lifting pad under the vehicle beam
and the lifting pad must be in line with the beam.
Retract the rear wheel of column to land the column steadily before the lifter lifts load, and make sure there is
no foreign articles such as hand tools, bolts, screw caps, small stones. No lifting during moving!