11-PROBLEMS/CAUSES/SOLUTIONS
CHECKING THE INTERNAL COMPONENTS
ATTENTION:
GUIDE FOR THE EXCLUSIVE USE OF THE SPECIALISED TECHNICIAN.
ATTENTION:
All repairs must be carried out exclusively by a specialised technician, with the boiler switched off and the plug
disconnected. The operations marked in bold type must be carried out by specialised personnel.
The manufacturer declines all liability and warranty terms expire if this condition is not complied with.
ANOMALY
POSSIBLE CAUSES
SOLUTIONS
The pellets are not fed into the
combustion chamber
The pellet hopper is empty
Fill the hopper with pellets
Sawdust has blocked the feed screw
Empty the hopper and remove the sawdust
from the feed screw by hand
Faulty gear motor
Replace the gear motor
Faulty electronic board
Replace the circuit board
The fire goes out or the boiler stops
automatically
The pellet hopper is empty
Fill the hopper with pellets
The pellets are not fed
See the previous anomaly
The pellet temperature safety probe has
been triggered
Let the boiler cool down, restore the
thermostat until the problem is resolved
and switch the boiler on again. If the
problem persists contact technical
assistance
The door is not closed properly or the
gaskets are worn
Close the door and replace the gaskets with
original ones
Unsuitable pellets
Change the type of pellets with those
recommended by the manufacturer
Low pellet supply
Have the fuel flow checked following the
booklet instructions
The combustion chamber is dirty
Clean the combustion chamber, following
instructions in the manual
Clogged outlet
Clean the smoke duct
Faulty smoke extraction motor
Check the motor and replace it, if necessary
Pressure switch faulty or defective
Replace the pressure switch