10-MAINTENANCE AND CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
When the boiler is cool, lift the front cover “
I
”; unscrew the screws on the rod “
D
” to clean the pipe unit and take out the two beams “
A
”.
Now take off the cover “
B
”. Then, take off screws “
V
” (two on the right and two on the left) that hold the turbulators to the boiler.
At this point, remove the four turbulators “
C
” and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.