44
10 - MENU ITEMS AND FUNCTION
SETTINGS MENU
The SETTINGS menu is for configuring use of the boiler:
a. Language.
b. Cleaning (shown only when boiler is off).
c. Auger loading (shown only when boiler is off).
d. Tones.
e. External thermostat (activation).
f. Auto Eco (activation).
g. Eco Turn-off T (default 10 minutes)
h. Pump on T (default 50°C).
i. Auxiliary boiler (default deactivated).
j. Pellet recipe.
k. Fumes rpm % ventilation.
l. Maximum power (1-5 - default 5).
m. Component test (shown only when boiler is off).
n. "Chimney sweeper" function (can be enabled only when boiler is on, for checking emissions in field).
o. System configuration (factory settings: system 02).
p. Season
q. Technical menu.
NOTE: Some of the options listed above cannot be enabled in certain "system configurations".
a - Language
Select the language as follows:
• Press the "menu" key.
• Use the arrow keys to scroll through and select "Settings"
• Press “menu” to confirm.
• Use the arrow keys to scroll through and select "language".
• Press “menu” to confirm.
• Use the + - keys to select the required language (IT/EN/DE/FR/ES/NL/PL/DA)
• Press "menu" to confirm and "esc" to exit.
b - Cleaning
Select "Cleaning" (only with boiler off) as follows:
• Press the "menu" key.
• Use the arrow keys to scroll through and select "Settings"
• Press “menu” to confirm.
• Use the arrow keys to scroll through and select ''Cleaning''
• Press “menu” to confirm.
• Use the + - keys to select "On".
• Press "menu" to confirm and "esc" to exit.